{"title":"6535C871 Series High Efficiency Two Ton Packaged Heat Pumps (Tecumseh Compressor)","description":"\u003ch1\u003e\u003ca\u003e6535C871 Series High Efficiency Two Ton Packaged Heat Pumps (Tecumseh Compressor)\u003c\/a\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/6535C871-1.jpg?v=1774412104\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/6535C871-2.jpg?v=1774412122\" alt=\"\"\u003e\u003c\/p\u003e","products":[{"product_id":"6535c3209-coleman-mach-a-c-control-board-kit","title":"6535C3209 Coleman-Mach A\/C Control Board Kit","description":"\u003ch1\u003e6535C3209 Coleman-Mach A\/C Control Board Kit\u003c\/h1\u003e\n\u003cp\u003eKeep your Coleman-Mach rooftop air conditioner functioning reliably with the 6535C3209 control board kit. This PCB assembly consolidates critical electrical functions onto a single device and includes the matching wiring harness to simplify installation and maximize system uptime.\u003c\/p\u003e\n\u003ch2\u003e🔧 Product Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility: Designed for Coleman-Mach 46515, 6535, and 6536 rooftop A\/C models.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eWiring Harness: Integrated wiring harness included to streamline installation and minimize field-wiring errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eFunctionality: Consolidates multiple control functions—compressor contactor, fan relay, thermostat interface—onto one PCB to improve reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eHousing: Green printed circuit board mounted on a rugged bracket; snap-in terminals for secure connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage Interface: AC-powered for 24VAC RV thermostat circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturer: Coleman-Mach\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e💡 Technician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways disconnect power and discharge any capacitors before servicing the control board.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect the wiring harness for frayed wires or corroded terminals; apply dielectric grease to maintain low-resistance connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify that mounting bracket holes line up with the OEM chassis to prevent PCB flex and connector strain.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitor relay actuation and check for chattering—an early sign of worn contacts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep the board dry and free of dust; use canned air to clear airflow sensors and status LEDs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"additional-attributes w-full\" style=\"width: 522.062px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd data-th=\"Brand\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003eColeman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eModel\u003c\/th\u003e\n\u003ctd data-th=\"Model\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003e6535C3209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eReplaces\u003c\/th\u003e\n\u003ctd data-th=\"Replaces\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003eColeman 6535-320, 6535A320, 6535B320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eColor\u003c\/th\u003e\n\u003ctd data-th=\"Color\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eIncluded\u003c\/th\u003e\n\u003ctd data-th=\"Included\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003e(1) Board\u003cbr\u003e(1) Gasket\u003cbr\u003e(9) Wires\u003cbr\u003e(3) Wire Nuts\u003cbr\u003eWiring Diagram and Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\" style=\"width: 126px;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\" style=\"width: 379.062px;\"\u003e7\" x 4-7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/6535C3209-SCHEMATICS_1024x1024.jpg?v=1683832939\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":16079286861890,"sku":"C6535C3209","price":347.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/th-2023-05-11T121028.701.jpg?v=1739520202"},{"product_id":"6536c3209-coleman-mach-6536-model-air-conditioner-board","title":"6536C3209 Coleman Mach 6536 Model Air Conditioner Board","description":"\u003ch2\u003e\u003cstrong\u003e6536C3209 Coleman Mach 6536 Model Air Conditioner Board \u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eNormal stocking item in our warehouse\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e6536C3209 Coleman‑Mach Control Board\u003c\/strong\u003e is the OEM replacement circuit board used in \u003cstrong\u003eColeman‑Mach 6536‑series rooftop air conditioners\u003c\/strong\u003e, providing the core logic for compressor control, fan operation, safety circuits, and communication with the thermostat. The product page you have open confirms the model number, replacements, and fitment details, making this the correct board for restoring proper operation in 6536‑series units. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e🧊 What this control board does\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis board manages the electrical and operational functions of the 6536 A\/C system, including compressor cycling, fan speeds, overload protection, and thermostat signal processing. When the original board fails—often due to heat stress, relay wear, or surge damage—symptoms may include no cooling, intermittent compressor operation, or fan issues. Installing the 6536C3209 restores OEM performance without requiring system rewiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey capabilities include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControls compressor and fan relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces with Coleman‑Mach thermostats\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides overload and safety logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect‑fit replacement for earlier 6536‑series boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBrand\u003c\/th\u003e\n\u003ctd data-th=\"Brand\" class=\"col data\"\u003eColeman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eModel\u003c\/th\u003e\n\u003ctd data-th=\"Model\" class=\"col data\"\u003e6536C3209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eReplaces\u003c\/th\u003e\n\u003ctd data-th=\"Replaces\" class=\"col data\"\u003e6535B320, 6536A320, 6536-3201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eFits\u003c\/th\u003e\n\u003ctd data-th=\"Fits\" class=\"col data\"\u003eColeman Mach 6536 Model Air Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eFeatures\u003c\/th\u003e\n\u003ctd data-th=\"Features\" class=\"col data\"\u003ePre-Wired PC Board, Simplifies Wiring\u003cbr\u003eConsolidates Several Of The Electrical Functions Onto One Device\u003cbr\u003eImproves The Reliability Of The Air Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eIncluded\u003c\/th\u003e\n\u003ctd data-th=\"Included\" class=\"col data\"\u003e(1) Pre-Wired PC Board\u003cbr\u003e(1) Red Wire Assembly\u003cbr\u003e(2) Black Wire Assembly\u003cbr\u003e(3) Wire Nuts\u003cbr\u003e(1) Wiring Diagram 1976J254 Sticker\u003cbr\u003e(1) Installation Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" class=\"col data\"\u003eBoard: 7\" L x 4-7\/8\" W\u003cbr\u003ePre-Wire Leads Yellow, Blue \u0026amp; Orange: 12\" L\u003cbr\u003ePre-Wire Leads Black\u0026amp; Red: 15\" L\u003cbr\u003eWire Assemblies: 7\" L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eWarranty\u003c\/th\u003e\n\u003ctd data-th=\"Warranty\" class=\"col data\"\u003eLimited 90 day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/6536C3209_480x480.jpg?v=1658548156\"\u003e\u003c\/p\u003e","brand":"Meyer Dis","offers":[{"title":"Default Title","offer_id":39419227471938,"sku":"C6536C3209","price":273.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th_30_687c5a1f-2608-49a4-a8f0-5f7b486be350.jpg?v=1626790784"},{"product_id":"1468a3029-coleman-a-c-1-3-hp-blower-motor","title":"1468A3029 Coleman A\/C 1\/3 HP Blower Motor","description":"\u003ch1\u003e1468A3029 Coleman A\/C 1\/3 HP Blower Motor\u003c\/h1\u003e\n\u003ctable class=\"additional-attributes w-full\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eBrand\u003c\/th\u003e\n\u003ctd data-th=\"Brand\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003eColeman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eModel\u003c\/th\u003e\n\u003ctd data-th=\"Model\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003e1468A3029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eColor\u003c\/th\u003e\n\u003ctd data-th=\"Color\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eFeatures\u003c\/th\u003e\n\u003ctd data-th=\"Features\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003e115V 60HZ\u003cbr\u003eAmps: 3.70\u003cbr\u003eHP: 1\/3\u003cbr\u003eRPM: 875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-th=\"Dimensions\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003eMotor Body: 5-5\/8\" Diameter x 5-3\/8\" Thick\u003cbr\u003eShaft: 8-5\/16\" L x 1\/2\" Diameter\u003cbr\u003eWire Leads Approx 13-1\/2\" L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd data-th=\"Net Weight\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003e14.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-b border-gray-300 last:border-b-0\"\u003e\n\u003cth scope=\"row\" class=\"col label w-1\/2 py-2 text-left text-gray-700 font-normal product-attribute-label\"\u003eGross Weight\u003c\/th\u003e\n\u003ctd data-th=\"Gross Weight\" class=\"col data w-1\/2 py-2 pl-2 text-left text-gray-900 product-attribute-value\"\u003e17.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":40364983025730,"sku":"C1468A3029","price":627.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/s-l960.jpg?v=1739506833"},{"product_id":"1499-5461-coleman-mach-rv-a-c-run-capacitor-7-5-mfd-370-vac","title":"1499-5461 Coleman-Mach RV A\/C Run Capacitor (7.5 MFD, 370 VAC)","description":"\u003ch1\u003e1499-5461 Coleman-Mach RV A\/C Run Capacitor (7.5 MFD, 370 VAC)\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 1499-5461 Run Capacitor delivers a stable energy supply to your Coleman-Mach rooftop air conditioner’s fan motor, ensuring consistent speed, reduced electrical noise, and extended motor life. Its heavy-duty oval metal housing and snap-in mounting design make installation straightforward and durable for demanding RV applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePart Number: 1499-5461\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMicrofarad Rating: 7.5 MFD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage: 370 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTerminals: Two-post, snap-in design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHousing Shape: Oval heavy-duty metal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeight: 2.89 oz (0.18 lb)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFits Coleman-Mach Series rooftop A\/C units, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e6700 Series (e.g., 6701B, 6702B, 6723A907)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e7000 Series (7332, 7333, 7335)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8000 Series (8332, 8333, 8335)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTotal model spans: 67\/733\/737\/753\/763\/833 series\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways match microfarad rating to original capacitor to prevent motor damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSigns of a failing run capacitor include humming motors, slow spin-up, or intermittent operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect for bulging, leaks, or corrosion—replacement at first sign extends compressor and motor life.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for inclusion in fan-motor rebuild kits or as a standalone part for preventative maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":42409644589122,"sku":"C1499-5461MC","price":24.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/1499-5461-2.webp?v=1755971395"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/collections\/6535C871-1.jpg?v=1774412150","url":"https:\/\/hvacpartstore.com\/collections\/6535c871-series-high-efficiency-two-ton-packaged-heat-pumps-tecumseh-compressor\/coleman-mach.oembed","provider":"HVACpartstore","version":"1.0","type":"link"}