{"title":"M7RL SERIES 95.1% AFUE DOWNFLOW GAS FURNACE PARTS","description":"\u003ch1\u003eM7RL SERIES 95.1% AFUE DOWNFLOW GAS FURNACE\u003c\/h1\u003e\n\u003cp\u003eM7RL SERIES SINGLE STAGE CONDENSING DOWNFLOW GAS FURNACE\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eModel Numbers: \u003c\/strong\u003eM7RL045A, M7RL060A, M7RL072A\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/M7RL_SERIES_parts_Page_1_1024x1024.jpg?v=1765415587\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/M7RL_SERIES_parts_Page_2_1024x1024.jpg?v=1765415637\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e","products":[{"product_id":"atc-3-bussmann-3-amp-fuse","title":"ATC-3 Bussmann 3 amp fuse","description":"\u003cp\u003e3 amp ATC fuse for circuit protection in many control boards. Rated up to 32V. Also known as part number ATC-3 and Nordyne 632261.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13005689539,"sku":"G32-189","price":2.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_342795913.jpeg?v=1739539785"},{"product_id":"1468-235p-a-coleman-5-5-blower-motor-1-2hp-115v-3-speed","title":"622341 Nordyne 24 VAC \/ 40 VA Control Transformer","description":"\u003cdiv role=\"article\" aria-labelledby=\"4ZpBRstxVBNZPo6T6emed-author 4ZpBRstxVBNZPo6T6emed-content-0\" data-content=\"ai-message\" data-tabster='{\"groupper\":{\"tabbability\":2},\"focusable\":{}}' tabindex=\"0\"\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"4ZpBRstxVBNZPo6T6emed-content-0\"\u003e\n\u003ch1\u003e622341 Nordyne 24 VAC \/ 40 VA Control Transformer\u003c\/h1\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Nordyne 622341R control transformer supplies stable 24 VAC power from a 120 VAC line for residential HVAC systems. As a direct-fit OEM replacement, it ensures reliable operation of thermostats, safety controls, relays, and valves by delivering consistent low-voltage output under varying load conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect replacement for Nordyne, Coleman, and compatible 40 VA transformers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design with dual mounting tabs for quick retrofit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-grade silicon steel laminations reduce heat and hum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFully encapsulated windings for vibration and moisture resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC ± 10 % @ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC ± 5 % @ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower rating\u003c\/td\u003e\n\u003ctd\u003e40 VA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eClass B (130 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e¼″ quick-connect spade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDual stamped mounting tabs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e3.0″ × 2.2″ × 2.0″ (76 × 56 × 51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 lb (0.50 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne 622341R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman 622341R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeuco 622341R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM legacy: 622329, 622341\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhite-Rodgers 90-353\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne and Coleman residential furnaces and air handlers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBryant 310A\/320A and Payne 355A control panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Standard N5\/P6 series heat pumps\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarrier\/Bryant 24 VAC systems requiring 40 VA transformers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAny HVAC control board designed for a 24 VAC @ 40 VA power source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways disconnect all power before servicing the transformer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify secondary voltage under load using a true-RMS meter; expect 24 VAC ± 5 %.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount firmly on a clean, vibration-free surface using the dual tabs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStrip wires cleanly and seat under spade terminals; torque screws to prevent arcing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAllow ½ inch clearance around the transformer for heat dissipation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep a spare 622341R on service calls to minimize customer downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e622341R 120 volt input, 24 volt output, 40VA. \u003cspan\u003e  Replaces 622329, \u003c\/span\u003e622341\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13111383811,"sku":"622329","price":37.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_554382506.jpg?v=1739539408"},{"product_id":"632337r-nordyne-on-off-toggle-switch","title":"632337R Nordyne on-off toggle switch","description":"\u003cp\u003eToggle switch, spst, curvette. Rated 16A at 125V or 10A at 250V. 2 wire connections. Face measures 5\/8\" x 1-3\/16\". Replaces 104993000 \u0026amp; 632337.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13195372739,"sku":"632337R","price":17.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_237674407.jpeg?v=1566072906"},{"product_id":"618107r-nordyne-zinc-pawl-latch-kit-1","title":"1036349R Nordyne zinc pawl latch kit","description":"\u003cp\u003e\u003c!--StartFragment --\u003e\u003c\/p\u003e\n\u003ch1\u003e1036349R Nordyne zinc pawl latch kit - OEM Furnace Door Latch\u003c\/h1\u003e\n\u003cp\u003eSecure your furnace panels with confidence using the \u003cstrong\u003eNordyne 1036349R Zinc Pawl Latch Kit\u003c\/strong\u003e, a genuine OEM replacement designed for durability and precision. Built from corrosion-resistant zinc, this latch ensures a tight, reliable seal for Nordyne, Intertherm, Miller, and Revolv furnace models.\u003c\/p\u003e\n\u003cp\u003e🔧 Key Features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Quality\u003c\/strong\u003e – Direct replacement for part numbers 618107R, 606275R, and 632330\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Zinc Construction\u003c\/strong\u003e – Resists wear, corrosion, and vibration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation\u003c\/strong\u003e – Designed for center twist-lock doors on M1, M3, and M7 series furnaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal Fit\u003c\/strong\u003e – Compatible with multiple Nordyne brands including Frigidaire, Gibson, and Tappan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e📦 Kit Includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e(1) Zinc pawl latch\u003c\/li\u003e\n\u003cli\u003eInstallation-ready hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIdeal for HVAC technicians and DIYers alike, this latch kit restores secure access to furnace compartments—keeping your system safe, efficient, and serviceable.\u003c\/p\u003e\n\u003cp\u003e\u003c!--EndFragment --\u003e\u003c\/p\u003e\n\u003cp\u003eUpgrade your plastic latch pawl to this metal one and never replace it again! Push nut included.\u003c\/p\u003e\n\u003cp\u003eReplaces 632230, 632230R, 606275 \u0026amp; 606275R, 618107R\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13403388291,"sku":"618107R","price":31.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/618107r-nordyne-zinc-pawl-latch-kit-3.jpg?v=1739538483"},{"product_id":"920915-nordyne-control-board-g7-single-stage","title":"920915 Nordyne OEM Control board G7 single stage","description":"\u003c!-- rlb --\u003e\n\u003ch1\u003e920915 Nordyne OEM Control board G7 single stage (1 year warranty)\u003c\/h1\u003e\n\u003cp\u003eNordyne control board. Also known as part number 624742 and 904840, \u003ca href=\"https:\/\/neuco.com\/ecommerce\/PartdetailAction?searchchoice=combined\u0026amp;partid=1495903\u0026amp;whichpage=1\u0026amp;photo=N\u0026amp;manu_name=all\u0026amp;timestamp=20250127213829\u0026amp;pid=\u0026amp;mc=xr\u0026amp;pvp=139005\"\u003e50M56X-843\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003eThis board will also replace a single stage G6\/L1 control board (# 624631) with a G7 control board (# 624690). \u003cbr\u003e\u003cbr\u003eFor a 2-stage board, order control board part number and 920916.\u003cbr\u003e\u003cbr\u003e\u003ca class=\"articles\" href=\"http:\/\/www.mobilehomerepair.com\/media\/img\/nordyne\/920915.pdf\"\u003eCLICK HERE\u003c\/a\u003e for flash codes and wiring diagrams.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13403393923,"sku":"920915 YUMA","price":150.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_263505819.jpeg?v=1566072616"},{"product_id":"632625-nordyne-nitride-ignitor","title":"632625 Nordyne Nitride ignitor.","description":"\u003cp\u003eNitride ignitor with 2-prong molex plug. 5\" wire lead. Typical found in Nordyne M7 and CMF95 furnaces.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13499709123,"sku":"632625","price":93.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/images_99.jpg?v=1739537981"},{"product_id":"626602","title":"626602 Nordyne 90–110 °F Auto-Reset Limit Switch","description":"\u003ch1\u003e626602 Nordyne 90–110 °F Auto-Reset Limit Switch\u003c\/h1\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 626602 Nordyne Auto-Reset Limit Switch is a direct-fit OEM safety control for residential gas furnaces and air handlers. Factory-preset to open at 90 °F and automatically reset at 110 °F, it provides reliable protection against low-limit conditions (such as blocked airflow) without requiring manual intervention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAuto-reset design for uninterrupted operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecision bi-metal sensing element for consistent actuation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact phenolic housing with snap-in mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCut-out temperature\u003c\/td\u003e\n\u003ctd\u003e90 °F (± 5 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset temperature\u003c\/td\u003e\n\u003ctd\u003e110 °F (± 5 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential\u003c\/td\u003e\n\u003ctd\u003e20 °F nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact configuration\u003c\/td\u003e\n\u003ctd\u003eSPST normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 250 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e¼″ quick-connect spade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature phenolic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting style\u003c\/td\u003e\n\u003ctd\u003eSnap-in or screw retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e1.25″ × 1.25″ × 0.75″ (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lb (23 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne 626602\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeuco 626602\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman 626602\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM legacy: L90-20AUTO, L90-110F auto reset\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with a wide range of single-stage residential furnaces and air handlers that require a 90 °F low-limit auto-reset switch, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne \u0026amp; Coleman N5\/N6 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGoodman \u0026amp; Amana legacy furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eYork \u0026amp; Westinghouse standard models\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBryant \u0026amp; Payne residential units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Standard Basic Heat \u0026amp; Pro-Line lines\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways disconnect power and verify zero voltage before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocate and remove the original low-limit switch; note its clip or bracket orientation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the 626602 in the identical plenum or duct location to ensure accurate temperature sensing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm terminal seating and torque spade connections per spec to avoid arcing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, restore power and allow normal cycling; the switch should stay closed under proper airflow and open only if the plenum temperature falls to 90 °F.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarry a spare 626602 and mounting clip for rapid field replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConsider bundling with airflow filters and blower wheel inspections to prevent recurring low-limit trips.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16078953513026,"sku":"626602","price":12.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/31HTtWqWuoL._SY445_SX342_QL70_ML2.jpg?v=1756262240"},{"product_id":"632492r","title":"632492R Nordyne PRESSURE SWITCH -0.50\"WC SPST","description":"\u003ch1\u003e632492R Nordyne PRESSURE SWITCH -0.50\"WC SPST\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 632492R Nordyne pressure switch monitors inducer draft in residential gas furnaces and air handlers, ensuring safe system performance by verifying that the inducer motor creates sufficient vacuum before ignition. Factory-set to actuate at –0.50\" water column, this direct-fit OEM replacement delivers consistent operation and accurate response to protect burners from unvented combustion conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint (trip pressure)\u003c\/td\u003e\n\u003ctd\u003e–0.50\" W.C. (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch type\u003c\/td\u003e\n\u003ctd\u003eDifferential vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact configuration\u003c\/td\u003e\n\u003ctd\u003eSPST; normally open until vacuum reached then closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof pressure\u003c\/td\u003e\n\u003ctd\u003e2.5\" W.C. (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurst pressure\u003c\/td\u003e\n\u003ctd\u003e5.0\" W.C. (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical rating\u003c\/td\u003e\n\u003ctd\u003e3 A @ 120 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet fitting\u003c\/td\u003e\n\u003ctd\u003e1\/8\" hose barb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003e¼\" quick-connect spade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e–40 °F to 180 °F (–40 °C to 82 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e2.0\" × 1.2\" × 1.3\" (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 lb (45 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne 632492R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne 632492\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman 632492R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRobertshaw PS205\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWhite-Rodgers 36D47\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFoster A501A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 632492R pressure switch fits a wide range of inducer-equipped gas furnaces and air handlers across major OEMs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne and Coleman N5, N6, P5, P6 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eYork and Westinghouse standard-efficiency units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGoodman and Amana GSX\/GMV series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBryant, Payne, and Rheem single-stage models\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Standard Basic Heat and Pro-Line lines\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways disconnect power and verify zero voltage before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse clean, flexible 1\/8\" tubing; avoid kinks and secure with proper clamps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount the switch in the original orientation and location to maintain calibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTest actuation with a calibrated manometer or vacuum pump: continuity should close at –0.50\" W.C. under suction and open at ambient.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect tubing and fittings for wear or leaks; replace as needed to ensure accurate performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCarry spare 632492R switches, tubing, and clamps on service calls for rapid field replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConsider bundling with inducer gaskets and control fuses to create a comprehensive safety-kit offering.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16078958264386,"sku":"632492R","price":31.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/OIP_4_43fd5bd0-f5eb-4db6-a119-46f5396a252b.webp?v=1756262823"},{"product_id":"667258r","title":"667258R Nordyne – 12\" x 8\" CW Galvanized Steel Blower Wheel","description":"\u003ch1\u003e667258R Nordyne – 12\" x 8\" CW Galvanized Steel Blower Wheel\u003c\/h1\u003e\n\u003ch3\u003e🌬️ 667258R – 12\" x 8\" CW Galvanized Steel Blower Wheel\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e667258R\u003c\/strong\u003e is a durable, double-inlet blower wheel engineered for \u003cstrong\u003eclockwise rotation\u003c\/strong\u003e in high-demand electric furnace and HVAC systems. Often referred to as a \"12x8,\" it features a galvanized steel construction for long-lasting performance in mobile home and residential applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e📐 Specs \u0026amp; Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e: 12\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 8\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRotation\u003c\/strong\u003e: Clockwise (CW) when viewed from shaft end\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e: Galvanized steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e: Silver\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 7.16 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e🔧 Compatibility\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eCommonly used in blower assemblies across:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eColeman\u003c\/strong\u003e: EB, EBX, EBV, 3400A, 3500A Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNordyne\u003c\/strong\u003e: E2EB, E2EH, M1GB\/M1GC, M1MC\/M1MD models\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompatible crossovers: \u003cstrong\u003eRBW11202\u003c\/strong\u003e, \u003cstrong\u003eLAU DD11-8A\u003c\/strong\u003e, \u003cstrong\u003eMars 41345\u003c\/strong\u003e, \u003cstrong\u003eMortex R69AB0002\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16078986870850,"sku":"667258R","price":115.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/667252-1.jpg?v=1752692291"},{"product_id":"903094","title":"903094 Nordyne BOTTOM COIL DOOR","description":"\u003ch1\u003e903094 Nordyne BOTTOM COIL DOOR\u003c\/h1\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 903094 bottom coil door is a genuine Nordyne OEM replacement panel that seals and protects the evaporator coil section of furnaces, air handlers, and packaged rooftop units. Manufactured from heavy-gauge galvanized steel with a durable powder-coat finish, it features an integrated EPDM gasket for an airtight seal. Pre-punched mounting holes and supplied screws simplify installation, ensuring proper airflow and condensate management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeavy-gauge galvanized steel construction with corrosion-resistant powder coat\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated EPDM gasket for leak-free fit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePre-punched mounting holes and included stainless-steel screws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFits coil compartment openings with up to 7″ cabinet depth\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWithstands operating temperatures from –40 °F to 180 °F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e903094\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003e22 gauge galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eTextured black powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGasket Material\u003c\/td\u003e\n\u003ctd\u003eEPDM rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e16.25 in × 21.50 in × 0.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.27 lb (1.94 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFour pre-punched holes with ¼″ spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFasteners Included\u003c\/td\u003e\n\u003ctd\u003eFour #8 × ¾″ stainless-steel screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–40 °F to 180 °F (–40 °C to 82 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis bottom coil door directly replaces Nordyne part 903094 and fits a wide range of Nordyne-branded and sister-brand units that share the same evaporator coil compartment dimensions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNordyne \/ Coleman \/ Comfortmaker\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAir handlers: 38AJ, 42AJ, 46AJ series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFurnaces: 38MJ, 42MV, 42MJ, FMPC, FMPM series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAmana \/ Ducane\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSplit-system air handlers: ACC, ACCP models (2–5 ton)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eGoodman \/ Intertherm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGMH9, DMH9 series furnaces and air handlers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079060041794,"sku":"903094","price":57.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/thumbnail_4e47d3cb-4eec-45a3-b913-df7393e9a7ec.jpg?v=1756708336"},{"product_id":"903977","title":"903977 Nordyne Door Assembly w\/Latch","description":"\u003ch1\u003e903977 Nordyne Door Assembly w\/Latch\u003c\/h1\u003e\n\u003ch1\u003e \u003c\/h1\u003e\n\u003ch3 id=\"part-num\"\u003e\n\u003ca href=\"https:\/\/colemanhvacparts.com\/products\/618107r-nordyne-zinc-pawl-latch-kit-1?_pos=1\u0026amp;_sid=4232aa93d\u0026amp;_ss=r\"\u003e618107R \u003c\/a\u003eReplacement Pawl Latch Kit\u003c\/h3\u003e\n\u003cdiv id=\"keywords\"\u003e\n\u003ch4\u003e\u003cbr\u003e\u003c\/h4\u003e\n\u003cdiv id=\"description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":16079064924226,"sku":"903977","price":166.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/R_973db7e7-1733-40b3-b3d7-6c96276cb19c.jpg?v=1756867625"},{"product_id":"904802","title":"904802 Nordyne Outlet Header Box","description":"\u003ch1\u003e904802 Nordyne Outlet Header Box\u003c\/h1\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 904802-outlet header box provides a centralized wiring junction for field power and control-harness connections in Nordyne and compatible OEM furnaces and air handlers. Constructed from galvanized steel with a powder-coat finish, it features multiple conduit knockouts, an integrated terminal strip, and a built-in ground lug. A gasketed, hinged cover offers dust and moisture protection, while stamped mounting flanges ensure a drop-in fit for upflow, downflow, horizontal, and multi-position installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGalvanated steel housing with durable powder-coat finish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1\/2″, 3\/4″, and 1″ knockouts for flexible conduit entry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlug-in terminal strip for control harness and field wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated ground lug for quick equipment grounding\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGasketed, hinged cover for environmental protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStamped mounting flanges for direct OEM replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUL and CSA listed for up to 600 VAC service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFurnace \/ AHU Model\u003c\/th\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003cth\u003eOrientation\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9MP048B1\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003eUpflow\u003c\/td\u003e\n\u003ctd\u003eStandard control-box location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9MP060B1\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9MF036A1\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003eUpflow\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9QC050A1\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE9MH040B1 (Coleman)\u003c\/td\u003e\n\u003ctd\u003eEnergy Plus\u003c\/td\u003e\n\u003ctd\u003eUpflow\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE9MH050C (Coleman)\u003c\/td\u003e\n\u003ctd\u003eEnergy Plus\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG8QA080E (Intertherm)\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG9QC070A2 (Concord)\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF9PA120A3 (Ducane)\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003eMulti-position\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG6MP036A1 (Nordyne AHU)\u003c\/td\u003e\n\u003ctd\u003eMulti-speed AHU\u003c\/td\u003e\n\u003ctd\u003eDownflow\u003c\/td\u003e\n\u003ctd\u003eAir-handler header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079068627010,"sku":"904802","price":158.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/R_6705a0fd-446c-425f-b811-38b5aa4715e5.jpg?v=1756679234"},{"product_id":"904951","title":"904951 Nordyne MOTOR MOUNT REPL KIT 13\"5.7D","description":"\u003ch1\u003e904951 Nordyne MOTOR MOUNT REPL KIT 13\"5.7D\u003c\/h1\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":16079069249602,"sku":"904951","price":50.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th_52_08ee92c6-6790-4fcc-b891-d84beda176da.jpg?v=1739524259"},{"product_id":"921597-nordyne-heat-exchanger","title":"921597 Nordyne HEAT EXCHANGER","description":"\u003ch1\u003e921597 Nordyne HEAT EXCHANGER\u003c\/h1\u003e\n\u003ch2\u003e\u003cstrong\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eMust ship Via Freight truck line \u003c\/span\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eIN STOCK \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e921597\u003c\/strong\u003e is the genuine OEM \u003cstrong\u003eheat exchanger assembly\u003c\/strong\u003e used in select Nordyne, Intertherm, and Miller furnaces. This component transfers heat from combustion gases into the circulating air stream while keeping flue gases safely contained.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBuilt to factory specifications, the 921597 restores proper heating performance, combustion efficiency, and safety. It is the direct replacement for systems originally equipped with this exchanger and installs without modification.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM Nordyne \/ Intertherm \/ Miller heat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures safe separation of flue gases and supply air\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestores proper furnace heating performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeavy‑gauge steel construction\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect replacement — no retrofit required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShips as a full assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Symptoms Requiring Replacement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCracked heat exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCO detector trips\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlame rollout or distortion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFurnace short‑cycling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible rust-through or heat stress\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":16079090352194,"sku":"921597","price":788.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/th_19_0629343b-58f6-43d3-998e-0a74e8ec6c5f.jpg?v=1739523818"},{"product_id":"to632624","title":"632624 Nordyne -0.70\"WC SPST PRESSURE SWITCH","description":"\u003ch1\u003e632624 Nordyne -0.70\"WC SPST PRESSURE SWITCH\u003c\/h1\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079328411714,"sku":"632624","price":37.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/632624r-3_bd3a46c6-0ed1-4f96-92b5-c4860f7726ca.jpg?v=1756683988"},{"product_id":"921494","title":"921494 Nordyne Inducer Assembly","description":"\u003ch1\u003e921494 Nordyne Inducer Assembly\u003c\/h1\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":40298060251202,"sku":"921494","price":415.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/R_856d02ae-4787-4056-b31e-4f9f42fbf031.png?v=1756518341"},{"product_id":"661135r","title":"661135R Nordyne Inshot Burner","description":"\u003ch1\u003e661135R Nordyne In shot Burner\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eThese are currently out of stock with a lead time at the end of December 2025\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e661135R is a genuine OEM Nordyne inshot burner designed for use in residential and light-commercial gas furnaces. Its compact 3.0 × 4.5 in profile ensures a direct fit in Nordyne, Nortek, and Miller-Nordyne combustion assemblies, delivering a stable flame pattern and reliable ignition performance\u003cspan class=\"mx-0.5 inline-block h-5 w-4 pb-1 align-middle\" data-copy=\"false\"\u003e\u003cbutton id=\":r1ga:\" aria-expanded=\"false\" aria-controls=\":r1g9:\" aria-label=\"Citation 2\" type=\"button\"\u003e2\u003c\/button\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurner type\u003c\/td\u003e\n\u003ctd\u003eInshot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel\u003c\/td\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.0 in × 4.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.33 lb (149.7 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHigh-grade steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eSpecifications compiled from Nordyne parts references and OEM data sheets\u003cspan class=\"mx-0.5 inline-block h-5 w-4 pb-1 align-middle\" data-copy=\"false\"\u003e\u003cbutton id=\":r1gf:\" aria-expanded=\"false\" aria-controls=\":r1ge:\" aria-label=\"Citation 3\" type=\"button\"\u003e3\u003c\/button\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e661135R\u003c\/td\u003e\n\u003ctd\u003eCurrent OEM inshot burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e661135\u003c\/td\u003e\n\u003ctd\u003eDiscontinued precursor; direct replacement by 661135R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThe original 661135 was discontinued in October 2022; 661135R supersedes it as the factory-authorized replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e661135R fits Nordyne and private-label furnaces built on the CMF95\/M7 and MG2 platforms, including (but not limited to):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne CMF95 and M7 series single-stage gas furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne MG2R and MG2S two-stage furnaces (e.g., MG2R072T, MG2S045T, MG2S060F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMiller-Nordyne and Nortek Global HVAC models sharing the same combustion assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify against the appliance’s data plate and service manual before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energize all electrical and gas supplies before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhotograph or label manifold orientation and burner bracket location.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemove the old burner; clean the manifold flange and replace the gasket if damaged.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeat the new burner fully against the gasket; tighten mounting screws evenly to OEM torque specs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestore power and gas, then initiate a heat call.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePerform a combustion analysis: verify stable flame pattern (blue cone), proper airflow, and no gas leaks with a leak-detection solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjust the air shutter or orifice as needed to optimize flame characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":40298070278210,"sku":"661135R","price":24.39,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/download_22_6130e7f7-5087-4187-beaa-87c1e2454836.jpg?v=1707104166"},{"product_id":"1046626-nordyne-gas-valve-1-2-x-3-8-24v-natural-or-lp-oem","title":"1046626 Nordyne 1\/2\" × 3\/8\" 24 VAC Natural or LP Gas Valve","description":"\u003cp\u003e\u003c!--StartFragment --\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1\u003e1046626 Nordyne 1\/2\" × 3\/8\" 24 VAC Natural or LP Gas Valve\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e1046626 is an official OEM Nordyne gas valve featuring 1\/2\" inlet and 3\/8\" outlet ports, a 24 VAC coil, and factory-converted orifice options for natural or LP gas applications. It delivers reliable first-stage control in Nordyne and Nordyne Miller furnaces, providing consistent ignition sequencing and diaphragm performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cp\u003eReplaces Nordyne 903956 \u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1046626\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNordyne 1\/2\" × 3\/8\" 24 VAC gas valve\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e903596\u003c\/td\u003e\n\u003ctd\u003eSuperseded Nordyne 1st-stage gas valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36J29-204P1\u003c\/td\u003e\n\u003ctd\u003eWhite-Rodgers LP-compatible gas valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne and Nordyne Miller gas furnaces originally equipped with 903596-series gas valves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrivate-label units using White-Rodgers 36J29-family valves, including Frigidaire, Intertherm, Coleman, Maytag, Gibson, GrandAire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplications requiring a 24 VAC valve input with 1\/2\" × 3\/8\" manifold connections for natural or LP gas service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways shut off the gas supply and relieve line pressure before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify fuel type: inspect orifices and conversion kit settings for natural (3.5\" WC) or LP (10\" WC) gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhotograph or diagram existing valve orientation, tubing, and wiring before removal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect manifold ports, tube fittings, and replace damaged hoses to prevent leaks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCheck coil resistance at 24 VAC; refer to OEM spec (typically 15–25 Ω).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLeak-test all joints with approved solution after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApply 24 VAC to the coil; listen for a crisp “click” indicating valve seating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMeasure outlet manifold pressure under live load: expect ~3.5\" WC (NG) or ~10\" WC (LP).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCycle multiple ignition sequences to confirm diaphragm integrity and consistent operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKit includes gas valve, elbow flange, mounting bracket, cap, plus short and long installation screws.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDownload the OEM valve technical datasheet (PDF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccess a printable cross-reference sheet for Nordyne and private-label gas valves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWatch our step-by-step video tutorial on gas valve replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e \u003c\/h1\u003e\n\u003cp\u003eUpgrade your HVAC system with the \u003cstrong\u003eNordyne 1046626 OEM Gas Valve\u003c\/strong\u003e, engineered for reliable performance across a wide range of Nordyne, Frigidaire, Intertherm, and other Nortek Global brands. This \u003cstrong\u003e1\/2\" x 3\/8\" 24V gas valve\u003c\/strong\u003e supports both \u003cstrong\u003enatural gas and LP applications\u003c\/strong\u003e, making it a versatile replacement for outdated or malfunctioning valves.\u003c\/p\u003e\n\u003cp\u003e🔧 \u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOEM part number: \u003cstrong\u003e1046626\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVoltage: \u003cstrong\u003e24V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eInlet\/Outlet size: \u003cstrong\u003e1\/2\" x 3\/8\"\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with natural gas and LP systems\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eDirect replacement for \u003cstrong\u003e36J29-204P1\u003c\/strong\u003e and \u003cstrong\u003e903596, 624610R\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eTrusted brands: Nordyne, Frigidaire, Intertherm, Tappan, Gibson, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e📦 \u003cstrong\u003eApplications:\u003c\/strong\u003e Ideal for residential and mobile home furnaces requiring precise gas flow control. Commonly used in Nordyne and White-Rodgers systems.\u003c\/p\u003e\n\u003cp\u003e💡 \u003cstrong\u003eWhy Choose OEM?\u003c\/strong\u003e Genuine OEM parts like the 1046626 ensure proper fit, safety, and long-term reliability—no guesswork, no compromises.\u003c\/p\u003e\n\u003cdiv class=\"product-description rte\"\u003egas valve for many Nordyne M-series furnaces with hot surface igntion. 1\/2\" gasline inlet on the right, 1\/2\" outlet on the left. Gas valve may be turned for side mounting. Comes set for natural gas. Replaces 624610.\u003cbr\u003e\u003cbr\u003eTo convert to propane (LP), simple unscrew cap marked 'NAT', flip over and screw back down so 'LP' shows on the cap. Also be sure to change your burner orifices when converting. Watch our 2-minute video below to see how the conversion is done.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cobject height=\"265\" width=\"320\"\u003e\u003cembed src=\"https:\/\/www.youtube.com\/v\/TARwavd1IJs\u0026amp;hl=en_US\u0026amp;fs=1\u0026amp;\" type=\"application\/x-shockwave-flash\" allowscriptaccess=\"always\" allowfullscreen=\"true\" width=\"320\" height=\"265\" title=\"Adobe Flash Player\"\u003e\u003c\/object\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-permalink=\"https:\/\/colemanhvacparts.com\/products\/624610r-nordyne-gas-valve-hsi\" class=\"social-sharing is-default\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003c!--EndFragment --\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":42329667305538,"sku":"1046626","price":185.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/903596-2_1024x1024_2x_6502b3a3-68b8-43c6-a512-21b4cf90f54e.webp?v=1753111266"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/collections\/M7RL_SERIES_parts_Page_1_574f5afd-7c7f-4512-a93c-b9a62c00388f.jpg?v=1765415697","url":"https:\/\/hvacpartstore.com\/collections\/m7rl-series-95-1-afue-downflow-gas-furnace-parts\/atc-fuse.oembed","provider":"HVACpartstore","version":"1.0","type":"link"}