{"title":"TM9V York Parts Breakdown","description":"\u003ch1\u003e\u003cstrong\u003eYork TM9V Furnace – Complete Parts Breakdown (Technician‑Ready)\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplies to:\u003c\/strong\u003e TM9V060, TM9V080, TM9V100, TM9V120 (all MP\/LP variants)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e1. Gas Train \u0026amp; Ignition Components\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHot Surface Ignitor:\u003c\/strong\u003e S1‑025‑32625‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGas Valve (2‑Stage):\u003c\/strong\u003e S1‑025‑41227‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBurner Orifices:\u003c\/strong\u003e Sized by BTU (natural\/LP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlame Sensor:\u003c\/strong\u003e S1‑025‑37461‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManifold Assembly:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBurner Box Gasket:\u003c\/strong\u003e S1‑029‑21010‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🌬 \u003cstrong\u003e2. Blower \u0026amp; Motor Assembly\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTM9V uses a \u003cstrong\u003etrue ECM variable‑speed motor\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eECM Blower Motor (1\/2–1 HP depending on model):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommon: \u003cstrong\u003eS1‑324‑40880‑007\u003c\/strong\u003e (1\/3 HP ECM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarger models: \u003cstrong\u003eS1‑324‑36041‑000\u003c\/strong\u003e (1 HP ECM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBlower Wheel:\u003c\/strong\u003e Diameter varies by model\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBlower Housing:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMotor Mount \/ Bracket:\u003c\/strong\u003e S1‑026‑XXXX (varies)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🌪 \u003cstrong\u003e3. Inducer Assembly\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInducer Motor:\u003c\/strong\u003e S1‑373‑19831‑002\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInducer Assembly:\u003c\/strong\u003e S1‑373‑19832‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInducer Gasket:\u003c\/strong\u003e S1‑029‑21009‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDrain Tubes \u0026amp; Collector Box:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e⚡ \u003cstrong\u003e4. Electrical \u0026amp; Control Boards\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMain Control Board (2‑Stage \/ ECM):\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eS1‑331‑03012‑000\u003c\/strong\u003e (your current tab)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTransformer:\u003c\/strong\u003e S1‑025‑32604‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLimit Switches:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrimary Limit: S1‑025‑32623‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRollout Switch: S1‑025‑32624‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePressure Switches:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e0.90\" WC: S1‑024‑39716‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1.21\" WC: S1‑024‑35779‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoor Switch:\u003c\/strong\u003e S1‑024‑35690‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🌡 \u003cstrong\u003e5. Sensors \u0026amp; Safeties\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlame Sensor:\u003c\/strong\u003e S1‑025‑37461‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Limit Switch:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRollout Switches:\u003c\/strong\u003e Manual reset\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Sensors:\u003c\/strong\u003e Integrated into board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e💧 \u003cstrong\u003e6. Condensate \u0026amp; Drain System\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondensate Trap:\u003c\/strong\u003e S1‑028‑XXXX (varies)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDrain Tubing Kit:\u003c\/strong\u003e Included with furnace\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCollector Box:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🧱 \u003cstrong\u003e7. Heat Exchanger \u0026amp; Cabinet\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Heat Exchanger:\u003c\/strong\u003e Welded aluminized steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Heat Exchanger:\u003c\/strong\u003e Stainless steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCabinet Insulation Panels:\u003c\/strong\u003e Model‑specific\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBurner Box Door:\u003c\/strong\u003e TM9V‑series standard\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🌀 \u003cstrong\u003e8. Venting Components\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVent Pressure Switch Tubing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVent Adapters (PVC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCombustion Air Intake Collar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch1\u003e📘 \u003cstrong\u003eTM9V Model‑Specific Notes\u003c\/strong\u003e\n\u003c\/h1\u003e\n\u003ch3\u003eTM9V100C16MP12C (your PDF tab)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e100,000 BTU input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e16\" cabinet width\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eECM variable‑speed blower\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e2‑stage gas valve\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUpflow \/ Horizontal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIf you want, I can generate a \u003cstrong\u003emodel‑specific breakdown\u003c\/strong\u003e for TM9V100C16MP12C only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_6_29b36049-d94d-4df0-8f9c-df21ef957fcf.jpg?v=1780340702\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_5_6848b061-7c1f-4497-878d-912170c39c30.jpg?v=1780340733\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_3_ed942383-3671-4d6f-99f7-27cb6871a64b.jpg?v=1780340746\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_6_1de764ae-1052-4eeb-876f-81fb6925212c.jpg?v=1780340760\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_5_2e945a01-9700-4b4e-b9c3-4deb29dd3375.jpg?v=1780340772\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_3_ef38ac2d-4dc0-4912-a84d-5e11bd0cf18d.jpg?v=1780340787\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"s1-025-32625-000-norton-271n-hot-surface-ignitor","title":"S1-025-32625-000 York Norton 271N Hot Surface Ignitor","description":"\u003ch2\u003eS1-025-32625-000 York Norton 271N Hot Surface Ignitor\u003c\/h2\u003e\n\u003cp\u003eReplaces 025-30385-700\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eS1-02532625000\u003c\/strong\u003e (York\/Coleman\/Luxaire hot surface igniter, Norton 271N style) is a silicon carbide igniter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor a \u003cstrong\u003enew, good igniter\u003c\/strong\u003e, the resistance should typically measure in this range:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e40–90 Ω (ohms)\u003c\/strong\u003e at room temperature (70°F \/ 21°C).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMost techs see them land right around \u003cstrong\u003e45–75 Ω\u003c\/strong\u003e fresh out of the box.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e⚡ \u003cstrong\u003eTesting tips\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways test with the igniter \u003cstrong\u003edisconnected\u003c\/strong\u003e from the furnace wiring harness.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse a digital multimeter set to the lowest resistance scale.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIf the reading is \u003cstrong\u003eopen (infinite resistance)\u003c\/strong\u003e or \u003cstrong\u003every low (under ~20 Ω)\u003c\/strong\u003e, the igniter is cracked or shorted and should be replaced.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHandle carefully—oils from your fingers or small impacts can shorten its life.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":39682407891010,"sku":"025-32625-000","price":78.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th-2022-01-25T094339.638.jpg?v=1739517113"},{"product_id":"s1-324-40880-007-york-240v-1-3hp-ecm-motor","title":"S1-324-40880-007 York 240v 1\/3hp ECM Motor","description":"\u003ch1\u003eS1-324-40880-007 York 240v 1\/3hp ECM Motor\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eNormal stocking Item\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eS1‑324‑40880‑007 York ECM Blower Motor (240V, 1\/3 HP)\u003c\/strong\u003e is the OEM constant‑torque electronically commutated motor used in select York, Luxaire, and Coleman HVAC air handlers and furnaces. This factory‑programmed motor delivers efficient, reliable airflow with reduced energy consumption compared to PSC motors. Designed as a direct replacement, it includes the integrated ECM module and arrives pre‑configured for the equipment family it supports. Ideal for restoring airflow in systems with failed or intermittent ECM motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv role=\"region\" aria-label=\"Scrollable table\" tabindex=\"0\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e240V \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHorsepower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1\/3 \u003c\/span\u003e\u003cspan\u003eHP \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eMotor \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eECM \u003c\/span\u003e\u003cspan\u003e(Constant \u003c\/span\u003e\u003cspan\u003eTorque)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eIntegrated \u003c\/span\u003e\u003cspan\u003eECM \u003c\/span\u003e\u003cspan\u003emodule\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e14.69 \u003c\/span\u003e\u003cspan\u003elb \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e9.25 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e9.55 \u003c\/span\u003e\u003cspan\u003e× \u003c\/span\u003e\u003cspan\u003e9.75 \u003c\/span\u003e\u003cspan\u003ein \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOEM\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYork\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eS1-32440880007\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":43286102409282,"sku":"S1-32440880007","price":586.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-04-01130823.png?v=1775088657"},{"product_id":"s1-331-03012-000-york-furnace-control-board-kit","title":"S1-331-03012-000 York Furnace Control Board Kit","description":"\u003ch1\u003eS1-331-03012-000 York Furnace Control Board Kit\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eS1‑331‑03012‑000\u003c\/strong\u003e is the OEM York furnace control board kit used in select York, Coleman, and Luxaire gas furnaces. This board manages ignition, blower timing, inducer operation, flame sensing, and all furnace safety circuits. It is the direct factory replacement for systems originally equipped with this control platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned to restore proper heating performance, this kit includes the updated control board and required installation components. Ideal for furnaces experiencing ignition failure, blower issues, intermittent heating, or fault‑code lockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eThis Control board is used in York TM9V series units \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM York \/ Johnson Controls control board kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports \u003cstrong\u003esingle‑stage and two‑stage\u003c\/strong\u003e furnace operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eControls ignition, blower sequencing, inducer, and safety circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect replacement — no wiring modifications required\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestores proper furnace performance and reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Symptoms Requiring Replacement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFurnace won’t ignite\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBlower won’t start or won’t shut off\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlashing fault codes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent heating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurnt or damaged board components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":43810424946754,"sku":"S1-331-03012-000","price":620.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/S1-331.png?v=1780339964"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/collections\/TG9S_TM9V_TM9X_CP9C_Commonly_Used_Parts.pdf_Page_6_61559cb5-e939-4351-a2f4-e9ebf9a103d5.jpg?v=1780341020","url":"https:\/\/hvacpartstore.com\/collections\/tm9v-york-parts-breakdown\/240v-ecm-motor.oembed","provider":"HVACpartstore","version":"1.0","type":"link"}