{"product_id":"025-36313-000-york-applied-spark-ignitor","title":"025-36313-000 York - Applied Spark Ignitor","description":"\u003ch1\u003e025-36313-000 York - Applied Spark Ignitor \u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e025-36313-000 York Applied Spark Ignitor\u003c\/strong\u003e is a genuine OEM ignition component designed for use in select York commercial and applied HVAC heating equipment. This spark ignitor generates the high-voltage spark required to ignite the fuel-air mixture during the burner startup sequence, ensuring reliable ignition performance and safe equipment operation. Manufactured to York and Source 1 specifications, the 025-36313-000 is engineered to provide dependable spark generation in demanding commercial heating applications.\u003c\/p\u003e\n\u003cp\u003eAs a critical part of the ignition system, this spark ignitor helps maintain proper burner operation, efficient combustion, and consistent heating performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e025-36313-000\u003c\/li\u003e\n\u003cli\u003e02536313000\u003c\/li\u003e\n\u003cli\u003eYork 025-36313-000\u003c\/li\u003e\n\u003cli\u003eApplied Spark Ignitor\u003c\/li\u003e\n\u003cli\u003eSpark Igniter\u003c\/li\u003e\n\u003cli\u003eIgnition Electrode\u003c\/li\u003e\n\u003cli\u003eBurner Ignitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine York \/ Source 1 OEM replacement spark ignitor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eSource 1\u003c\/li\u003e\n\u003cli\u003eJohnson Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYork Applied HVAC Equipment\u003c\/li\u003e\n\u003cli\u003eYork Commercial Heating Systems\u003c\/li\u003e\n\u003cli\u003eYork Rooftop Units\u003c\/li\u003e\n\u003cli\u003eYork Commercial Furnaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial heating systems\u003c\/li\u003e\n\u003cli\u003eApplied HVAC equipment\u003c\/li\u003e\n\u003cli\u003eGas-fired rooftop units\u003c\/li\u003e\n\u003cli\u003eCommercial furnaces\u003c\/li\u003e\n\u003cli\u003eSpark ignition systems\u003c\/li\u003e\n\u003cli\u003eBurner ignition assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIgnition Control Boards\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Ignition Cables\u003c\/li\u003e\n\u003cli\u003eIgnition Transformers\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eIgnition Wiring Harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM York ignition component.\u003c\/li\u003e\n\u003cli\u003eGenerates the spark required for burner ignition.\u003c\/li\u003e\n\u003cli\u003eEssential for reliable startup and proper combustion.\u003c\/li\u003e\n\u003cli\u003eInspect electrode condition when troubleshooting ignition failures.\u003c\/li\u003e\n\u003cli\u003eVerify proper spark gap according to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003eCheck ignition transformers, control boards, and high-voltage wiring before condemning the ignitor.\u003c\/li\u003e\n\u003cli\u003eInspect burner grounding and flame-proving components during service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNo spark during startup\u003c\/li\u003e\n\u003cli\u003eFailure to ignite\u003c\/li\u003e\n\u003cli\u003eIgnition lockout faults\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eWeak spark output\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eBurner startup failures\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify replacement part compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and connectors.\u003c\/li\u003e\n\u003cli\u003eCheck electrode condition and spark gap.\u003c\/li\u003e\n\u003cli\u003eInstall the ignitor using original mounting hardware.\u003c\/li\u003e\n\u003cli\u003eVerify proper alignment with the burner assembly.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eConfirm reliable spark and burner ignition.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIgnition control board\u003c\/li\u003e\n\u003cli\u003eHigh-voltage ignition cable\u003c\/li\u003e\n\u003cli\u003eIgnition transformer\u003c\/li\u003e\n\u003cli\u003eFlame sensor\u003c\/li\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003ePressure switch operation\u003c\/li\u003e\n\u003cli\u003eWiring harness condition\u003c\/li\u003e\n\u003cli\u003eCombustion air system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":46113000128578,"sku":"025-36313-000","price":125.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-20215626.png?v=1795237021","url":"https:\/\/hvacpartstore.com\/products\/025-36313-000-york-applied-spark-ignitor","provider":"HVACpartstore","version":"1.0","type":"link"}