{"product_id":"124930","title":"124930 AERCO Boiler and Water Heater BMK Annual Maintenance Kit","description":"\u003ch1\u003e124930 AERCO Boiler and Water Heater BMK Annual Maintenance Kit\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003e\u003cspan style=\"font-size: large; background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e The \u003cstrong\u003e124930 AERCO Boiler and Water Heater BMK Annual Maintenance Kit\u003c\/strong\u003e is designed for yearly upkeep of AERCO Benchmark boilers. It includes \u003cstrong\u003espark igniter, flame detector, condensate trap orifice, O-rings, and gaskets\u003c\/strong\u003e—all essential components to maintain combustion reliability, efficiency, and safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🔧 Technical Description\u003c\/h2\u003e\n\u003ch3\u003ePurpose\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnnual Preventive Maintenance\u003c\/strong\u003e: Ensures Benchmark boilers and water heaters operate at peak efficiency and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComponent Replacement\u003c\/strong\u003e: Provides factory-specified parts that wear or degrade over time, preventing performance loss or system failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKit Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpark Igniter\u003c\/strong\u003e – Replaces worn igniters to ensure consistent burner ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlame Detector\u003c\/strong\u003e – Maintains safe operation by reliably sensing flame presence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondensate Trap Orifice \u0026amp; O-Ring\u003c\/strong\u003e – Ensures proper condensate drainage and prevents leaks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eGaskets \u0026amp; Seals\u003c\/strong\u003e – Replace degraded seals to maintain airtight combustion and water-side integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"text-base-strong sm:text-lg-strong pb-1 [\u0026amp;:not(:first-child)]:pt-3.5\"\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003cstrong\u003eBenchmark Low NOx Boilers\u003c\/strong\u003e with separate igniter and injector assemblies (Nozzle Mix type).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCovers \u003cstrong\u003eall BMK sizes\u003c\/strong\u003e (up to 4000\/5000N models).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"text-base-strong sm:text-lg-strong pb-1 [\u0026amp;:not(:first-child)]:pt-3.5\"\u003eFunctionality\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIgnition Reliability\u003c\/strong\u003e: Fresh spark igniter and flame detector reduce misfires.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency Preservation\u003c\/strong\u003e: Clean seals and orifices prevent combustion inefficiencies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Assurance\u003c\/strong\u003e: Proper flame detection and condensate management reduce risk of unsafe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExtended Equipment Life\u003c\/strong\u003e: Prevents wear-related failures, keeping boilers in service longer.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e📊 Key Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePart \u003c\/span\u003e\u003cspan\u003eNumber\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e124930\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eKit \u003c\/span\u003e\u003cspan\u003eType\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eAnnual \u003c\/span\u003e\u003cspan\u003eMaintenance \u003c\/span\u003e\u003cspan\u003eKit\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eComponents \u003c\/span\u003e\u003cspan\u003eIncluded\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eSpark \u003c\/span\u003e\u003cspan\u003eigniter, \u003c\/span\u003e\u003cspan\u003eflame \u003c\/span\u003e\u003cspan\u003edetector, \u003c\/span\u003e\u003cspan\u003econdensate \u003c\/span\u003e\u003cspan\u003etrap \u003c\/span\u003e\u003cspan\u003eorifice, \u003c\/span\u003e\u003cspan\u003eO-ring, \u003c\/span\u003e\u003cspan\u003egaskets\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eCompatible \u003c\/span\u003e\u003cspan\u003eModels\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBenchmark \u003c\/span\u003e\u003cspan\u003eLow \u003c\/span\u003e\u003cspan\u003eNOx \u003c\/span\u003e\u003cspan\u003eBoilers \u003c\/span\u003e\u003cspan\u003e(Nozzle \u003c\/span\u003e\u003cspan\u003eMix, \u003c\/span\u003e\u003cspan\u003eall \u003c\/span\u003e\u003cspan\u003esizes)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003eMaintenance \u003c\/span\u003e\u003cspan\u003eInterval\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e12 \u003c\/span\u003e\u003cspan\u003emonths \u003c\/span\u003e\u003cspan\u003e(annual)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAERCO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePurpose\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003ePreventive \u003c\/span\u003e\u003cspan\u003emaintenance, \u003c\/span\u003e\u003cspan\u003eefficiency \u003c\/span\u003e\u003cspan\u003eretention, \u003c\/span\u003e\u003cspan\u003esafety \u003c\/span\u003e\u003cspan\u003eassurance\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e🛠️ Why It Matters\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnicians\u003c\/strong\u003e: Simplifies service calls with all required parts in one kit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOwners\/Operators\u003c\/strong\u003e: Reduces downtime, improves reliability, and ensures compliance with AERCO’s recommended maintenance schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e: Keeps boilers running at optimal combustion efficiency, lowering fuel costs and emissions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIn summary:\u003c\/strong\u003e The 124930 BMK Annual Maintenance Kit is a \u003cstrong\u003ecritical service package\u003c\/strong\u003e for AERCO Benchmark boilers, supplying the exact OEM parts needed to maintain safe ignition, proper flame detection, and leak-free operation on an annual basis.\u003c\/span\u003e\u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":39772337602626,"sku":"124930","price":568.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th_13_61417bc6-a252-47ec-9301-3cc65db8e703.jpg?v=1739516772","url":"https:\/\/hvacpartstore.com\/products\/124930","provider":"HVACpartstore","version":"1.0","type":"link"}