{"product_id":"2631-3481-coleman-oem-replacement-thermocouple-24-s1-7675-348","title":"2631-3481 Coleman OEM Replacement thermocouple 24\", S1-7675-348","description":"\u003ch1\u003e2631-3481 Coleman OEM Replacement Thermocouple 24\", S1-7675-348\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eFor the Older Model Mobile \/ Modular Home Furnace OEM Part With Standing Pilot \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecially made for older Coleman equipment 30mv 24\" and works awesome with the Coleman Gas valves 1 year warranty, don't be fooled by the knockoff's cheap universal thermocouples that may last for a few months but doesn't match the 30mv supply that could damage the gas valve, Buy OEM and keep your Coleman Furnace running for years to come. \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eColeman Commercial Product\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e🔧 Product Description: 2631-3481 Thermocouple\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Coleman (OEM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e: 24 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Continuous pilot thermocouple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Senses pilot flame and signals the gas valve to remain open. If no flame is detected, it shuts off gas flow to prevent unsafe conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e: Copper with brass fittings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e: Standard threaded nut for pilot burner assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Used in Coleman gas furnaces with standing pilot ignition systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003ch2 id=\"part-num\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eNormal Stocking Item 25\/26 Heating Season \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003ch3\u003e🔄 Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFits\u003c\/strong\u003e: Coleman mobile home and residential gas furnaces with continuous pilot systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommon Units\u003c\/strong\u003e: 7956A856, 7966A856, 7970A856, 7975A856, 7995A856, 8631A\/B\/C, 8632A\/B\/C, 8638A\/B\/C, and others using pilot ignition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Compatible with standing pilot assemblies—not for spark or hot surface ignition systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Universal fit for most Coleman pilot burners with 24\" reach\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e   1 year warranty \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e🧩 Replacement \u0026amp; Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003ch3\u003eDuo-therm number 714072-001\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2631-3481\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOriginal OEM part\u003c\/td\u003e\n\u003ctd\u003e24\" thermocouple, brass nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS1-7675-348\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYork\/Coleman alternate\u003c\/td\u003e\n\u003ctd\u003eSame specs, different packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2631-347\u003c\/strong\u003e, \u003cstrong\u003e2631-3471\u003c\/strong\u003e, \u003cstrong\u003e2631-348\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eLegacy Coleman numbers\u003c\/td\u003e\n\u003ctd\u003eInterchangeable with 2631-3481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e026-34038-000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOlder York\/Coleman part\u003c\/td\u003e\n\u003ctd\u003eOften replaced by 2631-3481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e631132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiller equivalent\u003c\/td\u003e\n\u003ctd\u003eSame length and thread, cross-compatible in some mobile home units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"keywords\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cdiv id=\"description\"\u003e\u003cstrong\u003eThermocouple\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Coleman 24\" thermocouple senses pilot light and closes gas valve if no flame sensed. Used in most all furnaces with a pilot light.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplaces 2631-347, 2631-3471, 2631-348, 2631-3481, 7675-3481, 026-34038-000, S1-7675-348, Q340A1074, 10P27, K17AT-24H, P671-0024, S1-2631-3481\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFunction \u0026amp; Application\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis thermocouple generates a small electrical signal when heated by the pilot flame. That signal keeps the gas valve open. If the pilot goes out, the thermocouple cools and shuts off gas flow to prevent unsafe conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA failing thermocouple can cause:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePilot not staying lit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFurnace not firing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent heating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePilot outages during windy or cold conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eReplacing it restores reliable pilot operation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13291395843,"sku":"S1-2631-3481","price":41.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/7675-348.jpg?v=1582003086","url":"https:\/\/hvacpartstore.com\/products\/2631-3481-coleman-oem-replacement-thermocouple-24-s1-7675-348","provider":"HVACpartstore","version":"1.0","type":"link"}