{"product_id":"3310710-003-dometic-a-c-shroud-for-hp-series","title":"ICM2805A Control Board Furnace Nordyne OEM Replacement","description":"\u003cdiv class=\"summary entry-summary\"\u003e\n\u003ch1 class=\"product_title entry-title\"\u003eICM2805A Control Board Furnace Nordyne OEM Replacement \u003c\/h1\u003e\n\u003cp class=\"price\"\u003e \u003c\/p\u003e\n\u003cdiv class=\"product_meta\"\u003e\u003cspan class=\"posted_in\"\u003eFURNACE CONTROL BOARDS,\u003cspan\u003e \u003c\/span\u003eNORDYNE REPLACEMENT BOARDS\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"short-sescription\"\u003e\n\u003ch2\u003e\u003cb\u003eNordyne OEM Replacement Control\u003c\/b\u003e\u003c\/h2\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eLow-Cost Form, Fit And Functional Replacement Board\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eThe ICM2805A is a low cost replacement for Nordyne 624631 furnace control board which is used to control gas valve, inducer draft motor, circulating blower and hot surface ignitor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost form, fit and functional OEM replacement control board for Nordyne: 624631\u003c\/li\u003e\n\u003cli\u003eFor use with G3, G4, G5, G6, M2 and M3 furnace modules\u003c\/li\u003e\n\u003cli\u003eControls gas valve, inducer draft motor, circulating blower and hot surface ignitor\u003c\/li\u003e\n\u003cli\u003eMonitors timing, trial for ignition, flame sensing, lockout, plus pressure, rollout and limit switches\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based precision\u003c\/li\u003e\n\u003cli\u003eTwinning compatible with another ICM2805A furnace control\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs aid in testing and troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eREPLACES:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNordyne:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e624631, 624631B (for use with G3, G4, G5, G6, M2 and M3 furnace modules)\u003c\/p\u003e\n\u003cp\u003eGeneric control board replaces Nordyne 624631 and 903106-kit.  Board is typically found on G3R, G4R, G5R Nordyne furnaces, among other models as listed below.  \u003c\/p\u003e\n\u003cp\u003eNordyne circuit board for M2 and M3 series of furnaces. Also used in G3, G4, G5 \u0026amp; G6 units. For a spare or replacement fuse, order 3A fuse G32-189.  To purchase the original version of this board, see part # 903106. \u003cbr\u003e\u003cbr\u003eReplaces 624538, 6245380, 624557, 6245570, 624564, 6245640, 624-5640, 624591, 6245910, 624628, 6246280, 624631, 624631A, 624631-A, 624631B, 624631-B, 6246310, 902378, 902696, 902896, 903106.\u003c\/p\u003e\n\u003ch3\u003eReplaces:\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNordyne:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e624631, 624631B (for use with G3, G4, G5, G6, M2 and M3 furnace modules)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan color=\"#FF0000\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan color=\"#FF0000\"\u003eCONTROL LIGHT STATUS\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRED\u003c\/span\u003e\u003cbr\u003eSteady ON Control OK\u003cbr\u003eSteady OFF No power\u003cbr\u003eRapid Flash - False flame or gas valve relay shorted\u003cbr\u003e1 Flash - Limit circuit open or external load on \"W\" (does not apply to deck switch, see below) .\u003cbr\u003e2 Flashes - Pressure switch is stuck open with inducer blower running.\u003cbr\u003e3 Flashes - Pressure switch is closed with inducer off\u003cbr\u003e4 Flashes - Ignition failure (check ground)\u003cbr\u003e5 Flashes 115 vac \u0026amp; neutral reversed or no ground\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eYELLOW\u003c\/span\u003e\u003cbr\u003eSteady ON - Good flame signal\u003cbr\u003eBlinking - Weak flame signal\u003cbr\u003eSteady OFF - No flame signal\u003c\/p\u003e\n\u003cp\u003eControl board operation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControls gas valve, inducer draft motor, circulating blower and hot surface ignitor\u003c\/li\u003e\n\u003cli\u003eMonitors timing, trial for ignition, flame sensing, lockout, plus pressure, rollout and limit switches.\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based precision\u003c\/li\u003e\n\u003cli\u003eTwinning compatible with another ICM2805 furnace control\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs aid in testing and troubleshooting\u003c\/li\u003e\n\u003cli\u003eIgnitor: 5A, 120 VAC\u003c\/li\u003e\n\u003cli\u003eCool Blower: 10A, 2HP, 240 VAC\u003c\/li\u003e\n\u003cli\u003eHeat: 5A, ½ HP, 250 VAC\u003c\/li\u003e\n\u003cli\u003eInducer Blower: 4A, 120 VAC\u003c\/li\u003e\n\u003cli\u003eGas Valve: 1A, 24 VAC\u003c\/li\u003e\n\u003cli\u003eHumidifier Motor: 0.5A, 24 VAC\u003c\/li\u003e\n\u003cli\u003eElectronic Air Cleaner: 1A, 120 VA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":13499704131,"sku":"ICM2805A","price":179.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/icm2805a-1_lg.jpg?v=1739538018","url":"https:\/\/hvacpartstore.com\/products\/3310710-003-dometic-a-c-shroud-for-hp-series","provider":"HVACpartstore","version":"1.0","type":"link"}