{"product_id":"58025-12-aerco-boiler-24-month-maint-kit-wtr-firesde","title":"58025-12 AERCO Boiler 24 MONTH MAINT KIT WTR\/FIRESDE","description":"\u003ch1\u003e58025-12 AERCO Boiler 24 MONTH MAINT KIT WTR\/FIRESDE\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking itemÂ \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAERCO 58025â€‘12 is the OEM 24â€‘Month Waterside\/Fireside Maintenance Kit\u003c\/strong\u003e for AERCO boilers and water heaters. Grounded distributor data confirms its identity, contents, and pricing across multiple reputable suppliers. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eðŸ”§ \u003cstrong\u003eCore Identity \u0026amp; Purpose\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 58025â€‘12 \u003cstrong\u003eComponent:\u003c\/strong\u003e 24â€‘Month Waterside\/Fireside Maintenance Kit \u003cstrong\u003eOEM:\u003c\/strong\u003e AERCO\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis is AERCOâ€™s \u003cstrong\u003efull twoâ€‘year service kit\u003c\/strong\u003e for Benchmark 5000\/6000 and other compatible AERCO systems. It includes all required components for both \u003cstrong\u003ewaterside\u003c\/strong\u003e and \u003cstrong\u003efireside\u003c\/strong\u003e inspection and replacement, ensuring the boiler remains safe, efficient, and codeâ€‘compliant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWe confirm the kit is used forÂ \u003cstrong\u003e24â€‘month inspection\u003c\/strong\u003e, including ignition and flameâ€‘safeguard components. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eðŸ“¦ \u003cstrong\u003eWhat the Kit Includes (Grounded)\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eGrounded listings confirm the following components:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpark igniter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlame detector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondensate trap orifice + Oâ€‘ring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional waterside\/fireside inspection components (gaskets, seals, cleaning hardware)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese align with AERCOâ€™s standard 24â€‘month maintenance structure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eUsed for scheduled 24â€‘month maintenance on:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Benchmark 5000\/6000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO commercial water heaters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOther AERCO systems requiring full waterside\/fireside service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTypical service outcomes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestored combustion efficiency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement of critical ignition and flameâ€‘safeguard components\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWaterside cleaning and gasket replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReduced downtime and improved longâ€‘term reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAERCO 58025â€‘12 24â€‘Month Waterside\/Fireside Maintenance Kit â€” OEM twoâ€‘year service kit for AERCO Benchmark 5000\/6000 boilers and compatible water heaters. Includes spark igniter, flame detector, condensate trap orifice with Oâ€‘ring, and all required waterside\/fireside components for full preventive maintenance. Restores combustion performance, improves reliability, and ensures safe, efficient operation.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558659579970,"sku":"58025-12","price":2448.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th_40_e3b8b4ef-03dc-4f8e-ad57-9da4ebf0c6c5.jpg?v=1739516859","url":"https:\/\/hvacpartstore.com\/products\/58025-12-aerco-boiler-24-month-maint-kit-wtr-firesde","provider":"HVACpartstore","version":"1.0","type":"link"}