{"product_id":"621919","title":"621919 Nordyne 1100 RPM 1-Speed Condenser Fan Motor","description":"\u003ch1\u003e621919 Nordyne 1100 RPM 1-Speed Condenser Fan Motor\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e621919 is an official OEM condenser fan motor engineered for Nordyne HVAC condensers. This permanent-split-capacitor (PSC) motor delivers 1\/10 HP at 1,100 RPM with clockwise rotation, running on 208–230 VAC. It restores optimal airflow and cooling performance in split-system air conditioners and heat pumps, ensuring energy-efficient operation and long service life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTechnical specifications are summarized in the table below, \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative max-w-full\"\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003ePermanent Split Capacitor (PSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208 V \/ 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e1,100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRotation\u003c\/td\u003e\n\u003ctd\u003eClockwise (CW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage\u003c\/td\u003e\n\u003ctd\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Diameter\u003c\/td\u003e\n\u003ctd\u003e0.5 in (½ in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Class\u003c\/td\u003e\n\u003ctd\u003eClass B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty\u003c\/td\u003e\n\u003ctd\u003eContinuous (S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e8.1 × 9.6 × 8.4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne OEM: 621919\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eNordyne Catalog: 01-0084\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eNordyne Alternative: 1014863R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eNortek Global HVAC: NOR621919\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for Nordyne split-system condensers and heat pumps requiring a 1\/10 HP, 1,100 RPM CW condenser fan motor on 208–230 VAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eDirect fit for models S4BD, S5BA, S6BF in 18 000 BTU and 24 000 BTU capacities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePSC design incorporates the run capacitor internally; no separate start capacitor needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eClean fan blades and housing at every service interval to prevent airflow restrictions and overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eWatch for these failure signs: fan won’t start, spins sluggishly, or emits rattling noises—always verify line voltage before replacing the motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eMounts in a standard 42-frame bracket using a ½ in shaft; confirm alignment of coupling and fan blade hub.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure replacement maintains clockwise rotation; swap blade orientation if system airflow dictates otherwise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16078937161794,"sku":"621919","price":164.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Nordyne_621919__87085.png?v=1756241245","url":"https:\/\/hvacpartstore.com\/products\/621919","provider":"HVACpartstore","version":"1.0","type":"link"}