{"product_id":"626599r-nordyne-160-f-manual-reset-inducer-limit-switch","title":"626599R Nordyne 160 Â°F Manual-Reset Inducer Limit Switch","description":"\u003ch1\u003e626599R Nordyne 160 Â°F Manual-Reset Inducer Limit Switch\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e626599R is an official OEM inducer limit switch with a 160 Â°F cut-out and manual-reset design, used on Nordyne and compatible furnaces to protect against overheating in the inducer compartment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\n\u003cstrong\u003eReplaces\u003c\/strong\u003e 626606\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCut-out temperature: 160 Â°F (72 Â°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReset style: Manual push-button\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact action: Normally closed; opens at cut-out temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnection: Quick-disconnect spade terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHousing material: High-temperature thermoset plastic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSpecifications compiled from Nordyne OEM data and parts suppliers\u003cspan class=\"mx-0.5 inline-block h-5 w-4 pb-1 align-middle\" data-copy=\"false\"\u003e\u003cbutton id=\":rqk:\" aria-expanded=\"false\" aria-controls=\":rqj:\" aria-label=\"Citation 2\" type=\"button\"\u003e2\u003c\/button\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eReplaces \/ Also Known As\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e626599R\u003c\/td\u003e\n\u003ctd\u003e626599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThis limit switch supersedes the earlier 626599 part number, streamlining inventory and ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne single-stage and multi-stage gas furnaces requiring a 160 Â°F manual-reset inducer limit switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMiller-branded and Intertherm units with equivalent switch requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMany private-label units under Westinghouse, Frigidaire, Gibson, and Tappan with identical specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify against the applianceâ€™s data plate or service manual before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energize all electrical and gas supplies before servicing the inducer assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTag and photograph existing switch wiring and mounting orientation for accurate reassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect inducer housing for debris or obstructions that can cause overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the new switch in the same location and orientation as the original to ensure correct temperature sensing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter mounting, initiate an inducer call: confirm the switch remains closed during normal operation and opens near 160 Â°F when the inducer is blocked or stalled.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePress the manual-reset button only after the assembly cools below the cut-in temperature; do not force inrush of power while the switch is open.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplace vacuum-sealed grommets or sealant around the switch fitting if air leaks are detected.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM wiring diagram \u0026amp; installation manual (PDF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrintable cross-reference cheat sheet for limit switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e626499R is an official OEM Limit Switch 145F with Manual Reset for Nordyne HVAC equipment.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45558108586050,"sku":"626599","price":17.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/OPHS_6c728e9d-f7c0-42eb-bb49-479dab9b3169.jpg?v=1750199170","url":"https:\/\/hvacpartstore.com\/products\/626599r-nordyne-160-f-manual-reset-inducer-limit-switch","provider":"HVACpartstore","version":"1.0","type":"link"}