{"product_id":"626608r","title":"626608R Nordyne Manual-Reset Rollout Switch 185 °F SPST","description":"\u003ch1\u003e 626608R Nordyne Manual-Reset Rollout Switch 185 °F SPST\u003c\/h1\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe 626608R rollout switch safeguards residential gas furnaces by interrupting the burner circuit if flame rollout or excessive heat is detected. Featuring a manual-reset design, it ensures technicians verify and clear fault conditions before returning the system to service. This direct-fit replacement offers reliable performance in Nordyne, Coleman, and many other OEM furnace models.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCut-out temperature\u003c\/td\u003e\n\u003ctd\u003e185 °F (85 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset method\u003c\/td\u003e\n\u003ctd\u003eManual push-button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact configuration\u003c\/td\u003e\n\u003ctd\u003eSPST normally closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 250 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal type\u003c\/td\u003e\n\u003ctd\u003e1\/4″ quick-connect spade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing material\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature phenolic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting style\u003c\/td\u003e\n\u003ctd\u003eSnap-in or screw retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (approx.)\u003c\/td\u003e\n\u003ctd\u003e1.25″ × 1.25″ × 0.75″ (L × W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead connection length\u003c\/td\u003e\n\u003ctd\u003eIntegrated quick-connect tabs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 lb (23 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne 626608R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeuco 1516781\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman 626608R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis rollout switch is compatible with a broad range of single-stage gas furnaces and air handlers, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne N5, N6 series furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman Legacy and Performance series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eYork\/Westinghouse standard furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBryant\/Payne single-stage models\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAmerican Standard Basic Heat and Pro-Line units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways de-energize the furnace and confirm zero voltage before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInstall the switch in the original rollout well or flame path, maintaining OEM orientation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter a trip, press the reset button only after diagnosing and correcting the cause of overheat or flame rollout.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify proper operation by running several heat cycles and confirming no nuisance trips occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKeep a spare 626608R on hand for fast replacement during service calls.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBundle with accompanying flame sensor and pressure switch for comprehensive safety-kit offerings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":40298071916610,"sku":"626608R","price":19.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/th_5_f0b5a1d3-2dfe-4c69-8f1a-663efc322e8c.jpg?v=1739507305","url":"https:\/\/hvacpartstore.com\/products\/626608r","provider":"HVACpartstore","version":"1.0","type":"link"}