{"product_id":"632432r-nordyne-pressure-switch","title":"632432R Nordyne Pressure Switch","description":"\u003ch1\u003e632432R Nordyne Pressure Switch\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e632432R is a genuine OEM Nordyne negative-pressure SPST air pressure switch that verifies inducer blower vacuum in gas furnaces and packaged units. It closes its normally open contact at â€“0.70\" water column to ensure proper draft before ignition, safeguarding combustion safety.Â \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Setpoint\u003c\/td\u003e\n\u003ctd\u003eâ€“0.70\" WC (closes on vacuum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eSPST normally open contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVacuum Port\u003c\/td\u003e\n\u003ctd\u003e1\/4\" barb fitting for vacuum tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals\u003c\/td\u003e\n\u003ctd\u003eTwo 1\/4\" male quick-connect spade lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e18â€“32 VAC (control interlock range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pointer-events-none absolute inset-0 rounded-lg border border-stroke-300 dark:border-stroke-450\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eEquivalent\/Notes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e632432R\u003c\/td\u003e\n\u003ctd\u003eOEM Nordyne replacement SPST pressure switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOR632432R\u003c\/td\u003e\n\u003ctd\u003eNortek Global HVAC equivalent (NOR632432R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pointer-events-none absolute inset-0 rounded-lg border border-stroke-300 dark:border-stroke-450\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFits Nordyne, Nordyne Miller, Intertherm, and private-label gas furnaces and packaged HVAC units originally equipped with a â€“0.70\" WC pressure switch. Always verify the appliance data plate or service manual pressure requirements and tubing connections before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energize power and lock out\/tag out both line voltage and 24 VAC control circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemove the access panel and locate the existing pressure switch on the inducer housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLabel or photograph vacuum tubing and spade-terminal connections for accurate reconnection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDepress the mounting tab to release the old switch; disconnect the vacuum hose and spade lugs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSnap the new 632432R into the factory bracket, seat the tubing on the 1\/4\" barb, and reconnect spade terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestore power and initiate a heat call; confirm the switch closes near â€“0.70\" WC and opens when vacuum falls below that threshold.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse a manometer or handheld pressure gauge to verify actuation accuracy and inspect tubing for leaks or kinks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplace any cracked tubing or damaged brackets to prevent nuisance lockouts and ensure long-term reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561368936514,"sku":"632432R","price":61.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/632432R__29834.jpg?v=1756246037","url":"https:\/\/hvacpartstore.com\/products\/632432r-nordyne-pressure-switch","provider":"HVACpartstore","version":"1.0","type":"link"}