{"product_id":"632444r-nordyne-pressure-switch-1-74","title":"632444R Nordyne Pressure Switch 1.74","description":"\u003ch1\u003e632444R Nordyne Pressure Switch\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e632444R is an official OEM –1.74\" WC SPST pressure switch for Nordyne HVAC equipment. It closes when the inducer or combustion air motor generates the required negative pressure, ensuring safe ignition and reliable system operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitch type: Single Pole Single Throw (SPST)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePressure setpoint: –1.74\" Water Column (WC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConnection: 1\/4\" barbed vacuum hose inlet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContact action: Normally open; closes upon reaching vacuum threshold\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHousing material: Durable plastic and metal components designed for high-temperature environments\u003cspan class=\"mx-0.5 inline-block h-5 w-4 pb-1 align-middle\" data-copy=\"false\"\u003e\u003cbutton id=\":rp3:\" aria-expanded=\"false\" aria-controls=\":rp2:\" aria-label=\"Citation 2\" type=\"button\"\u003e2\u003c\/button\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eCross-Reference \/ Legacy Numbers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e632444R\u003c\/td\u003e\n\u003ctd\u003e632444, 632252, 632252R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eThis switch supersedes multiple legacy Nordyne and Miller combusion-air switch part numbers, streamlining inventory management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne gas furnaces requiring a –1.74\" WC SPST switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntertherm, Miller, Tappan, Gibson, Frigidaire, White-Westinghouse, Philco, Garrison, Mammoth, Medallion units with equivalent pressure requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMany private-label models from Nortek Global HVAC with identical switch specifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify against the appliance’s data plate or service manual before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energize electrical and gas supplies before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTag and photograph existing vacuum tubing routing and terminal connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUse 1\/4\" vacuum hose rated for negative pressure; avoid kinks or restrictions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAfter installation, initiate an inducer call and confirm switch closure at –1.74\" WC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect hose fittings and switch terminals for leaks or corrosion; replace tubing if brittle.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM wiring diagram \u0026amp; installation manual (PDF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrintable cross-reference cheat sheet for pressure switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlso referred to as a combustion air switch or draft proving switch. -1.74. Switch closes when the combustion\/booster motor runs creating a negative air pressure. \u003cbr\u003e\u003cbr\u003eFor replacement tubing, order part # B13-614. \u003cbr\u003e\u003cbr\u003eReplaces 632252 and 632444.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13195373379,"sku":"632444R","price":31.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_538627464.jpeg?v=1566072901","url":"https:\/\/hvacpartstore.com\/products\/632444r-nordyne-pressure-switch-1-74","provider":"HVACpartstore","version":"1.0","type":"link"}