{"product_id":"89026-aerco-boiler-and-water-heater-neutralization-media","title":"89026 AERCO Boiler and Water Heater NEUTRALIZATION MEDIA","description":"\u003ch1\u003e89026 AERCO Boiler and Water Heater NEUTRALIZATION MEDIA\u003c\/h1\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse\u003c\/span\u003eÂ \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAERCO 89026 is the OEM Neutralization Media\u003c\/strong\u003e used in AERCO condensateâ€‘neutralization systems for boilers and water heaters. Grounded search results confirm its identity, chemistry, purpose, and pricing. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eðŸ”§ Core Identity \u0026amp; Function\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 89026 \u003cstrong\u003eComponent:\u003c\/strong\u003e Neutralization Media \u003cstrong\u003eOEM:\u003c\/strong\u003e AERCO\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis media is used inside AERCO condensateâ€‘neutralizer capsules to \u003cstrong\u003eraise the pH of acidic condensate\u003c\/strong\u003e produced by highâ€‘efficiency boilers and water heaters. Acidic condensate can corrode drains, piping, and sewer systems; this media prevents that damage by neutralizing acidity before disposal. Grounded documentation confirms it is the \u003cstrong\u003ereplacement media\u003c\/strong\u003e for AERCO neutralizer kits 89025â€‘1 and 89025â€‘2. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eðŸ“ Technical Characteristics\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eGrounded sources specify the media composition:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalcium carbonate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMagnesium oxide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese compounds dissolve gradually, raising condensate pH to safe levels. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional characteristics:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for all AERCO highâ€‘efficiency boilers \u0026amp; water heaters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEMâ€‘formulated for correct dissolution rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports plumbingâ€‘code compliance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUsed during routine maintenance or when neutralizer media is spent\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Benchmark\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Innovation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO KC1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Modulex\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Esteem\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAny AERCO system using neutralizer kits 89025â€‘1 or 89025â€‘2 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eUsed for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAnnual or semiâ€‘annual neutralizer maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement of depleted media\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtecting drains and piping from acidic condensate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAERCO 89026 Neutralization Media â€” OEM replacement media for AERCO condensateâ€‘neutralizer systems. Formulated with calcium carbonate and magnesium oxide to safely raise condensate pH, protect piping from corrosion, and maintain plumbingâ€‘code compliance. Fits AERCO neutralizer kits 89025â€‘1 and 89025â€‘2. Ideal for routine maintenance on highâ€‘efficiency boilers and water heaters.\u003c\/span\u003e\u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558656565314,"sku":"89026","price":120.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Pic_large_d6abf38d-8ee0-45fb-8ee1-b40b872cb7e3.webp?v=1739516737","url":"https:\/\/hvacpartstore.com\/products\/89026-aerco-boiler-and-water-heater-neutralization-media","provider":"HVACpartstore","version":"1.0","type":"link"}