{"product_id":"903110a-nordyne-ignitor-kit","title":"903110B Nordyne Hot Surface Ignitor Kit 120V, MG1E","description":"\u003ch1\u003e903110B Nordyne Hot Surface Ignitor Kit with Shield for older Nordyne Equipment\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e903110B is an OEM hot surface ignitor kit featuring a high-reliability silicon nitride element. It operates at 120 VAC and is engineered for MG1E series gas furnaces, providing rapid and consistent ignition in residential and light commercial heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElement material\u003c\/td\u003e\n\u003ctd\u003eSilicon nitride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical current\u003c\/td\u003e\n\u003ctd\u003e2.5 A (consult OEM manual for exact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead length\u003c\/td\u003e\n\u003ctd\u003e6 in high-temperature insulated wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting kit\u003c\/td\u003e\n\u003ctd\u003eInsulator bracket and mounting hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003ctable height=\"136\" style=\"width: 69.8529%; height: 143px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 58.8px;\"\u003e\n\u003cth style=\"width: 10.7967%; height: 58.8px;\"\u003eOEM Part Number\u003c\/th\u003e\n\u003cth style=\"width: 88.9799%; height: 58.8px;\"\u003eAlso Known As \/ Replaces\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 67.2px;\"\u003e\n\u003ctd style=\"width: 10.7967%; height: 67.2px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88.9799%; height: 67.2px;\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChoose 903110A\u003c\/strong\u003e if you specifically need a replacement \u003cstrong\u003ekit that includes the plug\/connector\u003c\/strong\u003e for a plug‑and‑play swap. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChoose 903110B\u003c\/strong\u003e if you need the \u003cstrong\u003e120V MG1E style ignitor with a silicon‑nitride element\u003c\/strong\u003e (the listing highlights the element material and spec). \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne MG1E series gas furnaces: MG1E130, MG1E150, MG1E180, MG1E200, MG1E250, MG1E280\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmerson\/Intertherm units built on the 50X57 MG1E platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrivate-label and OEM furnaces requiring a 120 VAC silicon nitride ignitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways verify model and voltage requirements against the furnace’s data plate before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisconnect all electrical power before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLabel or photograph the old ignitor’s wiring and bracket orientation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemove the existing ignitor; clean the mounting surface of debris.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePosition the new silicon nitride element in the insulator bracket—avoid bending or twisting the element.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure mounting hardware evenly; do not over-torque.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoute high-temperature leads clear of the combustion path.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRestore power and initiate a heat call; observe glow timing and flame rollout to confirm proper operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIf ignition faults occur, reference control board LED codes and verify flame sensor operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM installation manual \u0026amp; wiring diagram (PDF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrintable cross-reference cheat sheet for ignitor kits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNordyne ignitor for hot surface ignition (HSI) systems. This 120V nitride igniter now replaces the old silicone carbide ignitor. Nitride is designed to withstand more abuse and last longer. Installs the same as your old igniter.\u003c\/p\u003e\n\u003cp\u003eIgnitor glows to light flame on burner. It's also a flame sensor and will send signal to control board to shut down furnace if no flame is detected.\u003cbr\u003eReplaces 9031100, 903110, 632313 \u0026amp; 632313c.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13195393923,"sku":"903110B","price":98.07,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/903110B-1.png?v=1770137757","url":"https:\/\/hvacpartstore.com\/products\/903110a-nordyne-ignitor-kit","provider":"HVACpartstore","version":"1.0","type":"link"}