{"product_id":"904081","title":"904081 Nordyne 24 VAC ½″ Natural Gas Valve with LP Conversion Kit","description":"\u003ch1\u003e904081 Nordyne 24 VAC ½″ Natural Gas Valve with LP Conversion Kit\u003c\/h1\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e904081 is a genuine OEM Nordyne 24 VAC gas valve assembly with a ½″ port for natural gas and includes a propane (LP) conversion kit. Priced at $121.81 each, it ships with the factory LP conversion spring and hardware. Availability: 134 units in stock. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCross-Reference Part Numbers\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e904081\u003c\/td\u003e\n\u003ctd\u003eNordyne\u003c\/td\u003e\n\u003ctd\u003eOEM 24 VAC ½″ natural gas valve with LP conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e36E44\u003c\/td\u003e\n\u003ctd\u003eWhite-Rodgers\u003c\/td\u003e\n\u003ctd\u003eEquivalent universal 24 VAC ½″ valve kit, includes LP conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e720-553\u003c\/td\u003e\n\u003ctd\u003eRobertshaw\u003c\/td\u003e\n\u003ctd\u003eUniversal 24 VAC valve kit with LP\/Nat conversion springs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV4055B1014\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003ctd\u003eUniversal 24 VAC ½″ valve kit, LP kit included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eAlways verify cross-reference numbers with the original equipment manufacturer’s data plate or service manual.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis valve assembly directly replaces OEM valves on Nordyne, Miller-Nordyne, Coleman-Evcon, Ducane, and select private-label furnaces originally equipped with ½″ 24 VAC gas valves. Typical series and models include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNordyne G3, G4, G5, G6 and L1RA furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMiller-Nordyne Classic® and Platinum™ series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eColeman-Evcon II and Performance™ series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDucane state-of-the-art gas furnace lines\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eAlways confirm compatibility by matching the furnace model number and consulting the unit’s data plate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDe-energize all line-voltage and 24 VAC control power and shut off the gas supply before servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTag or photograph existing gas valve connections and manifold tubing to ensure accurate reassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount the replacement valve on the manifold flange; torque mounting screws per OEM specs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify 24 VAC at the valve coil terminals (R to C) before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor LP service, remove the natural gas spring and install the factory LP spring and orifice furnished in the kit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjust manifold pressure with a manometer: 3.5″ WC for natural gas, 10″ WC for propane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePerform a leak test on all tubing joints and manifold connections at 10″ WC air pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnergize the system and initiate a heat call; confirm proper valve opening, stable flame, and correct manifold pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eAdditional Resources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM Installation \u0026amp; Service Manual (PDF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrintable Gas Valve Conversion Checklist\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManifold Pressure Adjustment Chart\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVideo Tutorial: LP Conversion on Nordyne Valves\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":16079065940034,"sku":"904081","price":163.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th-2022-10-17T094418.450.jpg?v=1739524361","url":"https:\/\/hvacpartstore.com\/products\/904081","provider":"HVACpartstore","version":"1.0","type":"link"}