{"product_id":"b1809913s-goodman-control-module","title":"B1809913S Goodman control module HSI Board w\/9-Pin Connector","description":"\u003ch1\u003eB1809913S Goodman control module \u003cspan data-mce-fragment=\"1\"\u003eHSI Board w\/9-Pin Connector \u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003e Electronic control module measures 4.5\" x 5.75\". Includes 3 amp fuse, 4 plastic mounts \u0026amp; 2 wiring harnesses. Board contains 20 wire terminals. Used on GMP \u0026amp; GMPN series units. Also known as part number B18099-13 \u0026amp; B1809913. Replaces B18099-06, B18099-08 \u0026amp; B18099-10.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan color=\"#FF0000\" style=\"color: #ff0000;\"\u003eDiagnostic Flash Codes\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e1 flash - Lockout due to excessive retries.\u003cbr\u003e2 - Low stage pressure switch stuck closed.\u003cbr\u003e3 - Low stage pressure switch stuck open.\u003cbr\u003e4 - Open high limit.\u003cbr\u003e5 - Flame detected without gas valve.\u003cbr\u003e7 - Low flame signal.\u003cbr\u003e8 - Check igniter or improper ground.\u003cbr\u003e9 - High stage pressure switch stuck open.\u003cbr\u003eContinues flash - Reversed 115VAC polarity or check ignitor.\u003cbr\u003eOff - No power or internal control failure, replace board.\u003cbr\u003eOn - Normal operation.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13061128259,"sku":"B1809913S","price":75.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_272162761.jpeg?v=1739539753","url":"https:\/\/hvacpartstore.com\/products\/b1809913s-goodman-control-module","provider":"HVACpartstore","version":"1.0","type":"link"}