{"product_id":"baylpkt101a","title":"BAYLPKT101A Trane LP CONVERSION KIT","description":"\u003ch1\u003eBAYLPKT101A Trane LP CONVERSION KIT\u003c\/h1\u003e\n\u003cp data-path-to-node=\"0\" id=\"p-rc_6533fc8b3a4d6f88-22\"\u003e\u003cspan class=\"citation-11\"\u003eThe \u003c\/span\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"4\"\u003e\u003cspan class=\"citation-11\"\u003eTrane BAYLPKT101A\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-11 citation-end-11\"\u003e is a genuine OEM Liquid Propane (LP) conversion kit designed to safely convert compatible natural gas furnaces or packaged units to operate on liquid propane.\u003csup class=\"superscript embedded\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"1\"\u003eHere is a breakdown of its key details and specifications:\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eTechnical Overview\u003c\/h3\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\" id=\"p-rc_6533fc8b3a4d6f88-23\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eManufacturer:\u003c\/b\u003e\u003cspan class=\"citation-10 citation-end-10\"\u003e Trane \/ American Standard\u003csup class=\"superscript embedded\" data-turn-source-index=\"2\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\" id=\"p-rc_6533fc8b3a4d6f88-24\"\u003e\u003cspan class=\"citation-9\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-9\"\u003ePart Number:\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-9 citation-end-9\"\u003e BAYLPKT101A\u003csup class=\"superscript embedded\" data-turn-source-index=\"3\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\" id=\"p-rc_6533fc8b3a4d6f88-25\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003ePurpose:\u003c\/b\u003e\u003cspan class=\"citation-8 citation-end-8\"\u003e Modifies gas burner orifices and regulator settings to accommodate the higher energy density and pressure requirements of LP gas.\u003csup class=\"superscript embedded\" data-turn-source-index=\"4\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\" id=\"p-rc_6533fc8b3a4d6f88-26\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCompatibility:\u003c\/b\u003e\u003cspan class=\"citation-7 citation-end-7\"\u003e Typically used on single and two-stage gas packaged units and furnaces (frequently matching specific 60K, 64K, 90K, and 96K BTU models, such as the 4YCZ6 series).\u003csup class=\"superscript embedded\" data-turn-source-index=\"5\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eWhat’s Typically Included\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003ePropane burner orifices sized for specific BTU inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003eGas valve regulator spring or conversion components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003eConversion rating labels\/stickers to update the equipment safety plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003eInstallation instruction manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"6\"\u003e\n\u003cblockquote data-path-to-node=\"7\"\u003e\n\u003cp data-path-to-node=\"7,0\" id=\"p-rc_6533fc8b3a4d6f88-27\"\u003e⚠️ \u003cb data-path-to-node=\"7,0\" data-index-in-node=\"3\"\u003eSafety Notice:\u003c\/b\u003e Gas conversions modify critical combustion components. \u003cspan class=\"citation-6 citation-end-6\"\u003eFor safety and to maintain the manufacturer's warranty, this kit should strictly be installed by a licensed HVAC technician using a manifold pressure gauge to test for proper gas pressure \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":16079150645314,"sku":"BAYLPKT101A","price":34.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/BAY.png?v=1783001494","url":"https:\/\/hvacpartstore.com\/products\/baylpkt101a","provider":"HVACpartstore","version":"1.0","type":"link"}