{"product_id":"icm288","title":"ICM288 Furnace Control Board 62-24084-82","description":"\u003ch1\u003eICM288 Furnace Control Board 62-24084-82\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe ICM288 control is a low cost form, fit and functional replacement for Rheem 62-24084-82 circuit boards that monitors pressure, roll-out and limit switches. ICM288 controls gas valve, inducer draft motor, circulating blower and hot surface ignitor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"Box-sc-1z9git-0 ProductPageCollapse__CollapseContainer-sc-1edzdv1-2 gUKiTB hqsaiU\"\u003e\n\u003cdiv class=\"ProductPageCollapse__Collapse-sc-1edzdv1-0 bdmGel collapse show\"\u003e\n\u003cdiv class=\"Box-sc-1z9git-0 ProductPageDescription__ProductPageDescriptionContainer-sc-1i7espa-1 gUKiTB SvPIO\"\u003e\n\u003cdiv class=\"Box-sc-1z9git-0 gUKiTB ProductPageDescription__ProductPageDescriptionText-sc-1i7espa-2 hMvSxW\"\u003eGas Furnace Control Board - replacement for York\/Evcon 7990-319P control boards\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eLine Voltage Range: 98 to 132 VAC @ 60Hz\u003c\/li\u003e\n\u003cli\u003eIgnitor: 5A @ 120 VAC\u003c\/li\u003e\n\u003cli\u003eCool Blower: 10A, 2 HP, 240 VAC\u003c\/li\u003e\n\u003cli\u003eHeat: 5A, 1\/2 HP, 250 VAC\u003c\/li\u003e\n\u003cli\u003eInducer Motor: 4A, 120 VAC\u003c\/li\u003e\n\u003cli\u003eGas Valve: 1A @ 24 VAC\u003c\/li\u003e\n\u003cli\u003eHumidifier Motor: 0.5A, 24 VAC\u003c\/li\u003e\n\u003cli\u003e1A, 120 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eLow cost form, fit and functional replacement for Rheem 62-24084-82 circuit boards\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based design\u003c\/li\u003e\n\u003cli\u003eMonitors pressure, roll-out and limit switches\u003c\/li\u003e\n\u003cli\u003eControls gas valve, inducer draft motor, circulating blower and hot surface ignitor\u003c\/li\u003e\n\u003cli\u003eReverse polarity detection\u003c\/li\u003e\n\u003cli\u003eTwinning compatible with other ICM288 control boards\u003c\/li\u003e\n\u003cli\u003eDiagnostic LEDs for testing\/troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICM288 Furnace Control Module\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003ca data-citationid=\"ae3d4088-949a-de96-5d40-a1acbe71fb5d-4-group\" class=\"tooltip-target\" href=\"https:\/\/mans.io\/item\/icm\/icm288\" target=\"_blank\"\u003eThis control board is a low-cost replacement for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRheem 62-24084-82\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol boards\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eHere are the steps for installation and setup:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Precautions\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisconnect all power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the furnace before working on it.\u003c\/li\u003e\n\u003cli\u003eTo discharge your body’s electrostatic charge, touch your hand and tools to a clean, metal (unpainted) furnace surface near the control board.\u003c\/li\u003e\n\u003cli\u003eService the furnace only after grounding yourself.\u003c\/li\u003e\n\u003cli\u003eReground yourself if you touch ungrounded items.\u003c\/li\u003e\n\u003cli\u003eStore used and new controls separately to prevent electrostatic damage.\u003c\/li\u003e\n\u003cli\u003eConsider using an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESD service kit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent ESD damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Range: Line (98 to 132 VAC) @ 60Hz\u003c\/li\u003e\n\u003cli\u003eKey Ratings:\n\u003cul\u003e\n\u003cli\u003eIgnitor: 5A, 120 VAC\u003c\/li\u003e\n\u003cli\u003eFan Blower: 10A, 2 HP, 240 VAC\u003c\/li\u003e\n\u003cli\u003eHeat Blower: 5A, ½ HP, 250 VAC\u003c\/li\u003e\n\u003cli\u003eInducer Blower: 4A, 120 VAC\u003c\/li\u003e\n\u003cli\u003eGas Valve: 1A, 24 VAC\u003c\/li\u003e\n\u003cli\u003eHumidifier Motor: 10A, 120 VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTiming Parameters\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrepurge Heat: 60 seconds\u003c\/li\u003e\n\u003cli\u003ePrepurge Cool: 1 second\u003c\/li\u003e\n\u003cli\u003ePostpurge Heat: 90-180 seconds\u003c\/li\u003e\n\u003cli\u003ePostpurge Cool: 40 seconds\u003c\/li\u003e\n\u003cli\u003eTrial for Ignition: 10 seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIP Switch Settings\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSW1 Switches 1 \u0026amp; 2\u003c\/strong\u003e: Select the HEAT speed air blower off time delay (90, 120, 160, or 180 seconds). COOL speed air blower off time is fixed at 40 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSW1 Switches 3 \u0026amp; 4\u003c\/strong\u003e: Configure for single or TWIN systems and select 1st or 2nd stage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFan Pin Connections\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(P1 and P2):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eP1:\n\u003cul\u003e\n\u003cli\u003e1: N\/C\u003c\/li\u003e\n\u003cli\u003e2: 24 VAC Common\u003c\/li\u003e\n\u003cli\u003e3: Limit switch\u003c\/li\u003e\n\u003cli\u003e4: Gas valve\u003c\/li\u003e\n\u003cli\u003e5: Pressure switch OUT FAN\u003c\/li\u003e\n\u003cli\u003e6: Pressure switch IN\u003c\/li\u003e\n\u003cli\u003e7: Flame sensor\u003c\/li\u003e\n\u003cli\u003e8: Limit switch IN\u003c\/li\u003e\n\u003cli\u003e9: 24 VAC Common\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eP2:\n\u003cul\u003e\n\u003cli\u003e1: HSI\u003c\/li\u003e\n\u003cli\u003e2: N\/C\u003c\/li\u003e\n\u003cli\u003e3: 120 VAC Neutral\u003c\/li\u003e\n\u003cli\u003e4: Inducer\u003c\/li\u003e\n\u003cli\u003e5: N\/C\u003c\/li\u003e\n\u003cli\u003e6: 120 VAC Neutral\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCarefully remove all wiring from the OEM board and uninstall the OEM board from the furnace.\u003c\/li\u003e\n\u003cli\u003eInstall the ICM 288 board and reconnect wires as per the original installation.\u003c\/li\u003e\n\u003cli\u003eNote: Some furnace models require a separate flame sensor wired to pin 7 of the 9-pin harness if they lack a separate flame sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003ca data-citationid=\"ae3d4088-949a-de96-5d40-a1acbe71fb5d-82-group\" class=\"tooltip-target\" href=\"https:\/\/www.manualslib.com\/manual\/1453487\/Icm-Controls-Icm288.html\" target=\"_blank\"\u003eRemember to follow safety guidelines and consult the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eICM288 manual\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor specific details related to your installation\u003c\/a\u003e. If you have any doubts, consider seeking professional assistance. Stay warm and cozy!\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cbutton class=\"Box-sc-1z9git-0 jTgEWi ProductPageDescription__ProductPageDescriptionButtonReadMore-sc-1i7espa-0 gAsQsr\"\u003e\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":28490765467714,"sku":"ICM288","price":215.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/th_13_7c434a6b-f85a-4b81-af97-50f076e96448.jpg?v=1739518924","url":"https:\/\/hvacpartstore.com\/products\/icm288","provider":"HVACpartstore","version":"1.0","type":"link"}