{"product_id":"lh33zs004-carrier-ignitor-hot-surface","title":"LH33ZS004 Carrier Ignitor, Hot Surface","description":"\u003ch1\u003eLH33ZS004 Carrier Ignitor, Hot Surface\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eLH33ZS004 Carrier Hot Surface Ignitor\u003c\/strong\u003e is a genuine OEM replacement ignition component designed for use in select Carrier, Bryant, Payne, and related gas furnace applications. This hot surface ignitor (HSI) serves as the primary ignition source for the burner assembly, heating to ignition temperature and lighting the gas-air mixture during the furnace startup sequence. Engineered to Carrier factory specifications, the LH33ZS004 provides reliable ignition performance, efficient burner startup, and dependable heating system operation.\u003c\/p\u003e\n\u003cp\u003eManufactured for long service life and consistent performance, the LH33ZS004 is an essential replacement component when addressing ignition failures, no-heat conditions, or worn ignitor assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLH33ZS004\u003c\/li\u003e\n\u003cli\u003eCarrier LH33ZS004\u003c\/li\u003e\n\u003cli\u003eHot Surface Ignitor\u003c\/li\u003e\n\u003cli\u003eHSI Ignitor\u003c\/li\u003e\n\u003cli\u003eFurnace Ignitor\u003c\/li\u003e\n\u003cli\u003eCarrier Ignitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Carrier OEM replacement hot surface ignitor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eDay \u0026amp; Night\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eComfortmaker\u003c\/li\u003e\n\u003cli\u003eArcoaire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the furnace model and serial number before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eHot surface ignition systems\u003c\/li\u003e\n\u003cli\u003eResidential HVAC systems\u003c\/li\u003e\n\u003cli\u003eFurnace ignition assemblies\u003c\/li\u003e\n\u003cli\u003eHeating system repairs\u003c\/li\u003e\n\u003cli\u003eOEM replacement maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eFurnace Control Boards\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eDraft Inducer Motors\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eIgnition Wire Harnesses\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM Carrier ignition component.\u003c\/li\u003e\n\u003cli\u003eProvides reliable burner ignition during furnace startup.\u003c\/li\u003e\n\u003cli\u003eCritical component in the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eHandle carefully to prevent cracking or contamination.\u003c\/li\u003e\n\u003cli\u003eAvoid touching the ignitor element with bare hands.\u003c\/li\u003e\n\u003cli\u003eInspect flame sensor and burner condition during ignitor replacement.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignitor positioning and burner alignment before startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo glow from ignitor\u003c\/li\u003e\n\u003cli\u003eIgnition lockout faults\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eCracked ignitor element\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eNo heat condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with the furnace model.\u003c\/li\u003e\n\u003cli\u003eHandle the ignitor carefully to avoid damage.\u003c\/li\u003e\n\u003cli\u003eRemove the old ignitor and inspect wiring connections.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement ignitor using the original mounting hardware.\u003c\/li\u003e\n\u003cli\u003eVerify proper spacing and positioning.\u003c\/li\u003e\n\u003cli\u003eRestore power and initiate a heating cycle.\u003c\/li\u003e\n\u003cli\u003eConfirm proper ignitor glow and burner ignition.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensor condition\u003c\/li\u003e\n\u003cli\u003eBurner assembly cleanliness\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eDraft inducer performance\u003c\/li\u003e\n\u003cli\u003ePressure switch operation\u003c\/li\u003e\n\u003cli\u003eFurnace control board diagnostics\u003c\/li\u003e\n\u003cli\u003eWiring harness condition\u003c\/li\u003e\n\u003cli\u003eHeat exchanger inspection\u003c\/li\u003e\n\u003cli\u003eAir filter condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":46112278216770,"sku":"LH33ZS004","price":58.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-20195708.png?v=1795229842","url":"https:\/\/hvacpartstore.com\/products\/lh33zs004-carrier-ignitor-hot-surface","provider":"HVACpartstore","version":"1.0","type":"link"}