{"product_id":"s1-02435812000-york-pressure-switch-0-20wc","title":"S1-024-39716-000 York Pressure Switch -0.20\"wc","description":"\u003ch1\u003eS1-024-39716-000 York Pressure Switch -0.20\"wc\u003c\/h1\u003e\n\u003ch2\u003eReplaces \u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eS1-02435812000 \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cdiv id=\"keywords\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan\u003eThe \u003cstrong\u003eS1‑024‑39716‑000 York Pressure Switch –0.20\" WC\u003c\/strong\u003e is an OEM draft‑proving switch used in select York, Coleman, and Luxaire furnaces. Calibrated at \u003cstrong\u003e–0.20\" WC\u003c\/strong\u003e, this SPNO (normally open) switch closes on negative pressure to confirm proper inducer and vent performance before ignition.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eIf the furnace cannot achieve the required draft level, the switch remains open, preventing unsafe burner operation and protecting the heat exchanger from overheating or restricted airflow conditions.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eThis model is a common replacement for older York\/Coleman pressure switches that may look different due to manufacturer design updates. Function and calibration remain identical.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e S1‑024‑39716‑000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePressure Rating:\u003c\/strong\u003e –0.20\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e SPNO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAction:\u003c\/strong\u003e Closes on negative pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Draft\/combustion air proving\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReset:\u003c\/strong\u003e Automatic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOEM:\u003c\/strong\u003e York \/ Coleman \/ Luxaire\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eYork S1‑024‑39716‑000\u003c\/strong\u003e is a genuine OEM pressure switch rated at \u003cstrong\u003e–0.20\" WC\u003c\/strong\u003e, designed to monitor and verify proper draft and airflow in compatible York, Coleman, and Luxaire furnaces. This factory‑specified switch ensures safe ignition, reliable burner operation, and proper system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOEM York Component:\u003c\/strong\u003e Direct‑fit replacement engineered to match original system specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e–0.20\" WC Rating:\u003c\/strong\u003e Calibrated for precise low‑pressure sensing in induced‑draft furnace applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety‑Critical Function:\u003c\/strong\u003e Confirms correct airflow before allowing ignition, preventing unsafe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built with high‑quality diaphragms and contacts for long‑term reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTechnician‑Friendly:\u003c\/strong\u003e Straightforward installation with factory‑matched tubing and wiring connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eYork, Coleman, and Luxaire gas furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystems requiring a –0.20\" WC pressure switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplacement for failed, intermittent, or out‑of‑calibration switches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv id=\"keywords\"\u003e\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079222145090,"sku":"S1-02439716000","price":38.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-01-30_104523.png?v=1769795172","url":"https:\/\/hvacpartstore.com\/products\/s1-02435812000-york-pressure-switch-0-20wc","provider":"HVACpartstore","version":"1.0","type":"link"}