{"product_id":"s1-025-38252-000-coleman-heat-only-thermostat-oem","title":"S1-025-38252-000 Coleman Heat Only Thermostat OEM","description":"\u003ch1\u003eS1-025-38252-000 Coleman Heat Only Thermostat OEM\u003c\/h1\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv class=\"tab-pane active\" id=\"product_tab_1\"\u003eThermostat used on all Coleman furnaces with 2 wires at thermostat including units with A\/C.\u003cbr\u003eReplaces 025-35368-000, 7670-375, 7670-3751, 7966-375P, 7975-375P, 3400-3851, 7700-3751 \u0026amp; 7700-375P, S1-025-38252-000\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab-pane active\"\u003eDigital Options look at part numberÂ \u003ca title=\"https:\/\/colemanhvacparts.com\/products\/44-1025nc?_pos=2\u0026amp;_sid=ad28babee\u0026amp;_ss=r\" href=\"https:\/\/colemanhvacparts.com\/products\/44-1025nc?_pos=2\u0026amp;_sid=ad28babee\u0026amp;_ss=r\"\u003e1025NC\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eÂ \u003c\/p\u003e\n\u003cp\u003eInstalling a\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003e2-wire heat-only low voltage thermostat\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eis a straightforward process. Hereâ€™s a step-by-step guide to help you:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurn Off the Power\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBefore starting any wiring work,\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eturn off the power\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eto your heating system. You can do this by switching off the breaker that powers the thermostat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemove the Old Thermostat\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCarefully remove the cover from the old thermostat.\u003c\/li\u003e\n\u003cli\u003eNote the wires attached to it. Typically, there will be two wiresâ€”usually labeled\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003e(for heating) and\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eW\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003e(for the heat source).\u003c\/li\u003e\n\u003cli\u003eIf the wires are the same color, label each with the corresponding terminal letter using masking tape.\u003c\/li\u003e\n\u003cli\u003eLoosen the terminal screws and pull the wires from the terminals.\u003c\/li\u003e\n\u003cli\u003eRemove all mounting screws securing the thermostat base to the wall and take off the old thermostat.\u003c\/li\u003e\n\u003cli\u003eExamine the wire ends. Trim off any damaged portions and strip about 1\/2 inch of insulation from each wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMount the New Thermostat\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeparate the body of the new thermostat from its base plate following the manufacturerâ€™s instructions.\u003c\/li\u003e\n\u003cli\u003ePlace the base plate against the wall and use a level to ensure itâ€™s perfectly level.\u003c\/li\u003e\n\u003cli\u003eMark the holes for the mounting screws using a pencil.\u003c\/li\u003e\n\u003cli\u003eDrill pilot holes for the new mounting screws.\u003c\/li\u003e\n\u003cli\u003eAttach the base plate to the wall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Connections\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the wires to the new thermostat base:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR (heating)\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003ewire goes to the\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eterminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW (heat source)\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003ewire goes to the\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eW\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eterminal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIf thereâ€™s a jumper between\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eRC\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eand\u003cspan\u003eÂ \u003c\/span\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003cspan\u003eÂ \u003c\/span\u003eterminals (for central air or fan systems), remove it.\u003c\/li\u003e\n\u003cli\u003eInsert two AAA batteries into the new thermostat \u003cspan style=\"background-color: #ffff00;\"\u003e(if required)\u003c\/span\u003e and snap it onto the base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower On and Set Up\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurn the power back on.\u003c\/li\u003e\n\u003cli\u003eSet the time, temperature, and mode on the new thermostat according to the manufacturerâ€™s instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eRemember to follow safety precautions and consult the specific instructions provided with your thermostat. If you encounter any difficulties, consider seeking professional assistance. Stay warm!\u003cstrong style=\"background-color: #ffff00;\"\u003eÂ to prevent the potentiometer wire in the thermostat from getting hot and breaking, move the pointer to 1.2, so that the tail is sitting on the rivet that the white wire hooks to.Â \u003c\/strong\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561102106690,"sku":"S1-025-38252-000","price":79.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/S1-025-38252-000_Heat_Only_Thermostat.jpg?v=1582010491","url":"https:\/\/hvacpartstore.com\/products\/s1-025-38252-000-coleman-heat-only-thermostat-oem","provider":"HVACpartstore","version":"1.0","type":"link"}