{"product_id":"s1-33103494000","title":"S1-33103494000 2-Stage ECM Control Board Kit","description":"\u003cp\u003e\u003cspan\u003e2-Stage ECM Control Board Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp align=\"justify\"\u003eYork Furnace error codes are seen in three colors, red, green, and amber\/yellow. Each color will also flash a specific number of times to signify a specific error. Breaking down each color, and number of flashes, will help you solve the problem you are having with your York Furnace.\u003c\/p\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eSLOW GREEN FLASH\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eNormal operation\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eSLOW AMBER FLASH\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eNormal operation with call for heat\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eRAPID RED FLASH\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eTwinning error, incorrect 24V phasing.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCheck twinning wiring. Flame sense current is below 1.5 microamps\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eRAPID AMBER FLASH\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCheck and clean flame sensor. Check for proper gas flow. Verify that current is greater than 1.5 microamps at flame current test pad.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e4 AMBER FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe control is receiving a \"Y\" signal from the thermostat without a \"G\" signal, indicating improper thermostat wiring.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e1 RED FLASH\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis indicates that flame was sensed when there was not a call for heat.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe control will turn on both the inducer motor and supply air blower. A gas valve that leaks or is slow closing would typically cause this fault.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e2 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis indicates that the normally open pressure switch contacts are stuck in the closed position.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe control confirms these contacts are open at the beginning of each heat cycle. This would indicate a faulty pressure switch or miswiring. This indicates the normally open pressure switch contact did not close after the inducer was energized.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e3 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis could be caused by a number of problems: faulty inducer, blocked vent pipe broken pressure switch hose or faulty pressure switch.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e4 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis indicates that the main limit switch has opened its normally closed contacts.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe control will operate the supply air blower and inducer. This condition may be caused by: dirty filter, improperly sized duct system, incorrect blower speed setting, incorrect firing rate or faulty blower motor. Also, this fault code could be caused by a blown fuse located on the control board.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e5 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis fault is indicated if the normally closed contacts in the rollout switch opens.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe rollout control is manually reset. If it has opened, check for proper combustion air, proper inducer operation, and primary heat exchanger failure or burner problem. Be sure to reset the switch and cycle power (24 VAC) to the control after correcting the failure condition. Also, this fault code could be caused by a blown fuse located on the control board.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e6 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis indicates that after the unit was operating, the pressure switch opened 4 times during the call for heat.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eIf the main blower is in a \"Delay on\" mode, it will complete it, and any subsequent delay off period. The furnace will lock out for one hour and then restart.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e7 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis fault code indicates that the flame could not be established. This no-light condition occurred 3 times (2 retries) during the call for heat before locking out.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eLow gas pressure, faulty gas valve, dirty or faulty flame sensor, faulty hot surface ignitor or burner problem may cause this. The furnace will lock out for one hour and then restart.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e8 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis fault is indicated if the flame is lost 5 times (4 recycles) during the heating cycle.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis could be caused by low gas pressure, dirty or faulty flame sensor or faulty gas valve. The furnace will lock out for one hour and then restart.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e9 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eIndicates reversed line voltage polarity or grounding problem.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBoth heating and cooling operations will be affected. check polarity at furnace and branch. Check furnace grounding. Check that flame probe is not shorted to chassis.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e10 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eFlame sensed with no call for heat.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCheck gas valve and gas valve wiring This indicates that a primary or auxiliary limit switch has opened its normally-closed contacts and has remained open for more than five minutes.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e11 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis condition is usually caused by a failed blower motor or blower wheel.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCycle power (24 VAC) to the control to reset the hard lockout condition after correcting the failure condition.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e12 RED FLASHES\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis code indicates an open igniter circuit.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis could be a disconnected or loose wire or a cracked or broken igniter.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eSTEADY ON RED\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eControl failure.\u003cbr\u003e\u003cb\u003eFIX:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eReplace control board.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003e60-MINUTE AUTOMATIC RESET FROM LOCKOUT\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThis control includes a \"watchdog\" type circuit that will reset from a lockout condition after 60 minutes. Operational faults 6, 7, 8 will be reset. This provides protection to an unoccupied structure if a temporary condition exists causing a furnace malfunction. An example would be a low incoming gas supply pressure preventing unit operation When the gas pressure is restored, at some point the \"watchdog\" would restart the unit and provide heat for the house.\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv\u003e\n\u003cb\u003eCODE:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan color=\"red\"\u003eIGNITION CONTROL FLAME SENSE LEVELS\u003c\/span\u003e\u003cbr\u003e\u003cb\u003eRESULT:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eNormal flame sense current is approximately 3.7 microamps DC Low flame signal warning starts at 1.5 microamps. Low flame signal control lockout point is 0.1 microamps DC.\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079266545730,"sku":"S1-33103494000","price":307.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th-2022-12-23T123543.015.jpg?v=1739520520","url":"https:\/\/hvacpartstore.com\/products\/s1-33103494000","provider":"HVACpartstore","version":"1.0","type":"link"}