{"product_id":"s1-7900-6061-a","title":"7900-6061\/A Coleman 2 speed A\/C blower assembly 1 to 3 tons AC","description":"\u003ch1\u003e7900-6061\/A Coleman 2 speed A\/C blower assembly\u003cbr\u003e\n\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eBackorder from the factory \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"background-color: #ffff00;\"\u003eNOTE: when receiving a new blower unit the blower wheel will need to be adjusted and centered on the motor shaft and remove cardboard packing. They ship from the factory with the blower wheel pushed to the one side of the blower unit to keep the blower wheel in round position \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"background-color: #ffff00;\"\u003eto adjust loosen square head locking bolt and slide the blower wheel to the center of the motor shaft and make sure you have equal clearance on both sides of the blower assembly. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 SP AC BLOWER  \u003cspan\u003e2 speed A\/C blower assembly for gas furnaces. Used with air conditioners up to 3.0 tons. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you are looking for a replacement blower assembly for the Coleman 7600 series, COAS, COAT furnaces, this is a drop-in replacement. It will replace the old blower assembly with the included adapter plates. For units with air conditioners, you may have to add a transformer to the outside unit as the condenser units had the transformer in them during that era.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eColeman P\/N\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Motor\u003c\/td\u003e\n\u003ctd\u003e1468-220P\u003c\/td\u003e\n\u003ctd\u003e2-speed, 1\/3 HP, 1075 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower Wheel\u003c\/td\u003e\n\u003ctd\u003e026-24069-700\u003c\/td\u003e\n\u003ctd\u003e10″ × 7″ double-inlet, precision-balanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Clamp\u003c\/td\u003e\n\u003ctd\u003e7670-5391\u003c\/td\u003e\n\u003ctd\u003eRubber isolation mounts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun Capacitor\u003c\/td\u003e\n\u003ctd\u003e024-20063-700\u003c\/td\u003e\n\u003ctd\u003e7.5 µF, 440 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRubber Mounts\u003c\/td\u003e\n\u003ctd\u003e2702-4091\u003c\/td\u003e\n\u003ctd\u003eVibration-damping mounts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegacy Assembly\u003c\/td\u003e\n\u003ctd\u003e7900-6031 \/ S1-7900-6031\/A\u003c\/td\u003e\n\u003ctd\u003eOriginal replacement part numbers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eInstallation and adjustment guidelines for the 7900-6061\/A assembly:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemove all cardboard shipping blocks before powering up.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLoosen the square-head locking bolt and slide the blower wheel to center it on the motor shaft; confirm equal clearance on both sides.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVerify 120 VAC at motor terminals and correct 9-pin Molex connections before start-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsure the 7.5 µF run capacitor is properly seated and rated at 440 VAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdapter plates are provided for Coleman 7600-series, COAS, and COAT furnaces; confirm hole-pattern alignment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCompatible applications and common OEM models for the 7900-6061\/A blower assembly:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsed to replace existing blower when adding air conditioning to an existing heat only system or 3-1\/2 tons or more A\/C to a new system\u003c\/li\u003e\n\u003cli\u003eUsed when adding 3 tons or less A\/C to Evcon gas furnaces that are not A\/C ready or MGHA or MMHA series Nordyne gas funaces, or when adding 3 tons of A\/C to DGAT\/C or DGAT\/D series Evcon furnaces less than 90,000 BtuH input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003cth\u003eModels \/ Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eColeman Gas Furnaces\u003c\/td\u003e\n\u003ctd\u003e7600 series, COAS, COAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSplit-System Air Conditioners\u003c\/td\u003e\n\u003ctd\u003eUp to 3.0 ton condenser units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegacy Replacement\u003c\/td\u003e\n\u003ctd\u003eReplaces 7900-6031 \/ S1-7900-6031\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftermarket Retrofits\u003c\/td\u003e\n\u003ctd\u003e10″ × 7″ blower housings in range hoods or light commercial units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eColeman 7900-6061\/A blower assembly\u003c\/strong\u003e is designed for \u003cstrong\u003e1 to 3 ton A\/C systems\u003c\/strong\u003e, and typically produces \u003cstrong\u003eapproximately 800 to 1,200 CFM\u003c\/strong\u003e depending on static pressure and speed setting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e🔧 Key Specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMotor\u003c\/strong\u003e: 2-speed, 1\/3 HP, 1075 RPM (P\/N 1468-220P)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBlower Wheel\u003c\/strong\u003e: 10\" × 7\" double-inlet (P\/N 026-24069-700)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCFM Range\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLow Speed\u003c\/strong\u003e: ~800–900 CFM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Speed\u003c\/strong\u003e: ~1,000–1,200 CFM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eReplaces the 7900-6031 S1-7900-6031\/A.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":16079291842626,"sku":"S1-7900-6061\/A","price":813.05,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/7900_6061A.jpg?v=1739520119","url":"https:\/\/hvacpartstore.com\/products\/s1-7900-6061-a","provider":"HVACpartstore","version":"1.0","type":"link"}