{"product_id":"water-heater-control-wt8840a1000-water-heater-gas-valve-standing-pilot-with-piezo-setpoint-55-155f-spud-length-1-bracket-offset-reg-setting-4-wc-natural-gas","title":"Water Heater Control WT8840A1000 Water Heater Gas Valve, Standing Pilot With Piezo.","description":"\u003ch2 data-mce-fragment=\"1\"\u003eWater Heater Control\u003c\/h2\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"pageDescription\" id=\"pageDescription\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eWT8840A1000 Water Heater Gas Valve, Standing Pilot With Piezo, Setpoint 55-155F, Spud Length 1\", Bracket=offset, Reg Setting 4\" WC, Natural Gas\u003c\/h3\u003e\n\u003cdiv class=\"description-box\"\u003e\n\u003cdiv class=\"description\"\u003e\n\u003cspan\u003ePart Description:\u003c\/span\u003e\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eWater Heater Control\u003c\/li\u003e\n\u003cli\u003eItem Water Heater Control\u003c\/li\u003e\n\u003cli\u003eType 90 Degree\u003c\/li\u003e\n\u003cli\u003ePort Connection 1\/2 Inch Threaded x 1\/2 Inch Inverted Flare\u003c\/li\u003e\n\u003cli\u003eInput Supply Rating 350 to 850 Millivolt DC\u003c\/li\u003e\n\u003cli\u003eTemperature Rating 0 to 150 Deg F\u003c\/li\u003e\n\u003cli\u003ePressure Rating 4 Inch WC\u003c\/li\u003e\n\u003cli\u003eMedia Handled Gas\u003c\/li\u003e\n\u003cli\u003eInclusions\/Features Integrated NTC Temperature Sensor\u003c\/li\u003e\n\u003cli\u003eApplication Water Heater\u003c\/li\u003e\n\u003cli\u003eApplicable Standard CSA 6.20\/4.6, CAN\/CSA C22.2, ANSI Z21.20\/Z21.23\/Z21.78\/Z21.87\u003c\/li\u003e\n\u003cli\u003eTank Insulation Size 1 Inch\u003c\/li\u003e\n\u003cli\u003eAmbient Temperature 32 to 150 Deg F, -40 to 150 Deg F (Storage), 55 Deg F to 155 Deg F Valve (Set Point)\u003c\/li\u003e\n\u003cli\u003eMounting Position Upright\u003c\/li\u003e\n\u003cli\u003eCapacity 30 Foot per 3 Hour to 75 Foot per 3 Hour\u003c\/li\u003e\n\u003cli\u003eHumidity 95 Percent (Non-Condensing) at 104 Deg F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eUPC: \u003c\/span\u003e 085267567398\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePart Number:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eWT8840A1000\/U\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003eReplaces Part Numbers:\u003c\/strong\u003e \u003cspan data-mce-fragment=\"1\"\u003e WV8840A1000, WV8840A1001, 222-47463-01A, 222-47463-01E, or 239-47463-01\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"features\"\u003e\n\u003ch2\u003eFeatures \/ Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWt8840 Water Heater Control is Designed for Use in Standing Pilot Applications Using an Immersion Well for Water Temperature Sensing\u003c\/li\u003e\n\u003cli\u003eThe Wt8840 is Powered from a Thermopile Heated by the Standing Pilot Flame\u003c\/li\u003e\n\u003cli\u003eTemperature Control as Well as Water Temperature Limit Function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"1\" cellpadding=\"3\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eMANUFACTURER \u003c\/td\u003e\n\u003ctd\u003eHONEYWELL RESIDENTIAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eMANUFACTURER PART NUMBER \u003c\/td\u003e\n\u003ctd\u003eWT8840A1000\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eMETROPAC INTERNAL PART NUMBER \u003c\/td\u003e\n\u003ctd\u003e321588\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eADDITIONAL INFORMATION \u003c\/td\u003e\n\u003ctd\u003eTank Insulation Size 1 Inch; Ambient Temperature 32 to 150 Deg F, -40 to 150 Deg F (Storage), 55 Deg F to 155 Deg F Valve (Set Point); Mounting Position Upright; Capacity 30 Foot per 3 Hour to 75 Foot per 3 Hour; Humidity 95 Percent (Non-Condensing) at 104 Deg F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eMARKETING TEXT \u003c\/td\u003e\n\u003ctd\u003eThe WT8840 series is the Water Heater Control for trade use to replace WV8840 valves used in AOSmith and Bradford White Water Heaters. It is designed for use in Standing Pilot applications using an immersion well for water temperature sensing. An included integrated NTC temperature sensor reads water temperature within the appliance up to 221 F (105 C).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003ePRODUCT NAME \u003c\/td\u003e\n\u003ctd\u003eWater Heater Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd nowrap\u003eUPC CODE \u003c\/td\u003e\n\u003ctd\u003e085267567398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":32485179818050,"sku":"WT8840A1000\/U","price":284.33,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/HNYWLL_WT8840A1000-U_Image1.jpg?v=1739517717","url":"https:\/\/hvacpartstore.com\/products\/water-heater-control-wt8840a1000-water-heater-gas-valve-standing-pilot-with-piezo-setpoint-55-155f-spud-length-1-bracket-offset-reg-setting-4-wc-natural-gas","provider":"HVACpartstore","version":"1.0","type":"link"}