Old Electric Furnace Adding Air Conditioning Step by Step Guide

Old Electric Furnace 3400 Adding Air Conditioning 

✅ Parts List for Adding A/C to a Coleman 3400‑820 Furnace

(All parts below are compatible with the 3400‑820 and match items on your product page.)

A. Required Indoor Parts (Furnace Side)

1. A/C Control Box

  • 3400‑5841 — Coleman A/C control box
    • Includes: 24V transformer, fan relay, terminal strip
    • This is the heart of the conversion.

2. Blower Upgrade (Required for A/C Airflow)

The 3400 heat‑only blower is too weak for cooling. Use one of these:

  • S1‑3500‑6901/A — 4‑speed blower assembly, 1–3 ton (fits 3400)

If you ever need 4–5 ton:

  • 3500‑7901/A — 4‑speed 3/4HP blower (fits 3400 cabinet)

3. Low‑Voltage Controls

  • 3300‑3861 — 24V 40VA transformer (spare or replacement)
  • 025‑38747‑000 — 4‑wire heat/cool thermostat
  • 18/5 thermostat cable
  • 18/2 low‑voltage cable to outdoor unit (Y + C)

4. Indoor Coil & Drain

Pick based on tonnage:

  • S1‑S1831 — 1.5–3 ton mobile home A‑coil
  • S1‑6324‑5101 — 18" x 19.5" drip pan
  • 3240‑3051 — condensate trap

5. Misc Indoor Electrical

  • Wire nuts, spade terminals
  • Label tape
  • Furnace service switch (if missing)

B. Outdoor Parts (Condenser Side)

1. Outdoor Condenser

  • 2–3 ton straight cool (brand doesn’t matter)

2. Electrical

  • 3400‑3261 — Coleman/Nordyne disconnect assembly
  • Outdoor whip
  • Proper breaker (per condenser MCA/MOP)
  • Copper wire sized to condenser nameplate

3. Refrigerant Circuit

  • Line set (suction + liquid) sized to tonnage
  • Condensate tubing
  • Optional: float switch

✅ Text Wiring Diagram (Technician‑Friendly)

Below is a clean, accurate wiring layout using the 3400‑5841 control box.

1. Transformer (Inside 3400‑5841)

Primary (240V):

  • L1 → Transformer primary
  • L2 → Transformer primary

Secondary (24V):

  • R = 24V hot
  • C = 24V common

2. Thermostat Wiring

Thermostat Terminal

Connects To (3400‑5841)

Function

R

R

24V power

C

C

Common

G

G

Indoor blower (cool)

Y

Y

Outdoor condenser

W

Furnace heat circuit

Heat elements

3. Outdoor Condenser Wiring

  • Y (control box) → One side of outdoor contactor coil
  • C (control box) → Other side of outdoor contactor coil

When stat calls for cooling:

  • R → Y energizes condenser contactor
  • R → G energizes blower relay

4. Blower Motor Wiring (Critical for A/C)

Neutral/Common:

  • White → Neutral block

Heat Speed Tap:

  • Medium/low → Furnace heat relay (existing 3400 wiring)

Cool Speed Tap:

  • High → Fan relay output from 3400‑5841

Only one speed tap is energized at a time.

5. Line Voltage Overview

Furnace

  • 240V supply → Furnace lugs
  • Feeds: heat elements, blower motor, transformer/control box

Condenser

  • 240V supply → Breaker → Outdoor disconnect → Condenser
  • Low‑voltage Y/C only energizes contactor coil

 

Internal Components of the 3400‑5841 A/C Control Box

(This is the exact internal architecture used in the 3400‑series electric furnaces when adding A/C.)

1. 24‑Volt Transformer (Step‑Down)

  • Primary: 240V
  • Secondary: 24V
  • Output: ~40VA
  • Function: Supplies low‑voltage power for thermostat, Y/G/W circuits, and outdoor contactor coil.

This transformer is the same spec as 3300‑3861.

2. Fan Relay (Blower Cool‑Speed Relay)

  • Coil: 24V
  • Contacts: SPST (normally open)
  • Function:
    • Energizes cool/high‑speed blower tap when thermostat calls for G or Y.
    • Isolates heat‑speed circuit from cool‑speed circuit.

This is the relay that makes the 3400 blower A/C‑capable.

3. Terminal Strip (Low‑Voltage Distribution Block)

Labeled terminals include:

  • R – 24V hot
  • C – 24V common
  • G – Blower relay coil
  • Y – Outdoor condenser contactor
  • W – Heat call (passes through to furnace heat circuit)

This is the connection point for thermostat and outdoor unit.

4. High‑Voltage Feed Block

  • L1/L2 feed from furnace
  • Supplies transformer primary
  • Supplies fan relay line voltage output to blower motor cool‑speed tap

5. Blower Cool‑Speed Output Lead

  • Typically a blue or black lead depending on model
  • Connects to blower motor high‑speed tap
  • Energized only when relay closes

6. Internal Wiring Harness

  • Pre‑terminated spade connectors
  • Color‑coded low‑voltage harness
  • High‑temp insulated high‑voltage leads
  • Connects transformer, relay, and terminal strip together

📦 Summary Table — Internal Parts of 3400‑5841

Component

Function

Notes

24V Transformer

Powers thermostat & condenser contactor

Same spec as 3300‑3861

Fan Relay (24V coil)

Switches blower to cool speed

SPST, normally open

Terminal Strip

R, C, G, Y, W distribution

For stat + outdoor unit

High‑Voltage Feed Block

Supplies transformer & relay

Ties into furnace L1/L2

Cool‑Speed Output Lead

Sends 240V to blower high‑speed

Only energized in cooling

Internal Harness

Pre‑wired connections

Color‑coded

                     ┌──────────────────────────────────────────┐

                     │         3400‑5841 CONTROL BOX             │

                     └──────────────────────────────────────────┘

 

 LINE VOLTAGE (FROM FURNACE)

 ┌───────────────┐

 │   L1    L2     │  240V SUPPLY

 └─────┬─────┬────┘

       │     │

       │     │

       │     └───────────────────────────────┐

       │                                     │

       ▼                                     ▼

 

   ┌──────────────────────────────┐

   │      TRANSFORMER (24V)       │

   │   Primary: 240V (L1/L2)      │

   │   Secondary: R / C           │

   └──────────┬───────────┬──────┘

              │           │

              │           │

              ▼           ▼

            (R)         (C)

              │           │

              │           │

              │     ┌───────────────┐

              │     │ TERMINAL STRIP│

              │     │ R  C  G  Y  W │

              │     └───────────────┘

              │       │  │  │  │  │

              │       │  │  │  │  └───→ W → Furnace heat circuit

              │       │  │  │  └──────→ Y → Outdoor contactor

              │       │  │  └─────────→ G → Fan relay coil

              │       │  └────────────→ C → Common to stat & condenser

              │       └───────────────→ R → 24V hot to stat

 

 