3L01-120 Limit Copeland Comfort Control (White Rodgers) 110°F	120°F

3L01-120 Limit Copeland Comfort Control (White Rodgers) 110°F 120°F

  • $ 14.95
    Unit price per 
  • Save $ 10.04
Shipping calculated at checkout.


3L01-120 Limit Copeland Comfort Control (White Rodgers) 110°F    120°F

The 3L01-120 Snap Disc Limit Switch (60T11-610000) is an automatic reset temperature safety control designed to protect HVAC and heating equipment from overheating. Featuring a 120°F fixed cut-out temperature and 110°F fixed cut-in temperature, this open-on-rise snap disc switch interrupts the control circuit when temperatures exceed safe operating limits and automatically resets after cooling.


Cross-Reference

  • 3L01-120
  • 3L01120
  • 60T11-610000
  • White-Rodgers 3L01-120
  • Copeland Comfort Control 3L01-120

Direct OEM

White-Rodgers 3L01-120


Compatible Brands

  • Copeland
  • White-Rodgers
  • Emerson
  • Universal HVAC Applications
  • Heat Pumps
  • Refrigeration Equipment
  • HVAC Control Systems

Application

Used in heating and cooling equipment to:

  • Protect components from overheating
  • Open the circuit when temperature rises to 120°F
  • Automatically reset when temperature falls to 110°F
  • Protect compressors and control circuits
  • Prevent excessive operating temperatures

Related Components

  • Snap Disc Limit Switch
  • Fan Switch
  • High Limit Control
  • Defrost Control
  • Transformer
  • Compressor Contactor
  • Control Board
  • Temperature Sensor

Technician Notes

The 3L01-120 is an automatic reset, open-on-rise limit switch. The contacts remain closed during normal operation and open when the sensed temperature reaches 120°F. Once the temperature cools to 110°F, the contacts automatically reset. When replacing, ensure the switch action, temperature ratings, mounting style, and electrical specifications match the original part.


Common Symptoms of Failure

  • Equipment shuts down unexpectedly
  • Open safety circuit
  • Compressor fails to operate
  • Intermittent operation
  • Nuisance temperature trips
  • No continuity through switch
  • Control board safety lockout
  • Heating or cooling system interruptions

Installation Tips

  1. Disconnect power before servicing.
  2. Verify the replacement temperature ratings match the original.
  3. Confirm switch action is "Open on Rise."
  4. Mount firmly against the original sensing surface.
  5. Inspect terminals for overheating or corrosion.
  6. Check system airflow and operating temperatures.
  7. Verify switch operation after installation.
  8. Test complete system operation before returning equipment to service.

Recommended Inspection Items

  • Airflow across equipment
  • Compressor operating temperature
  • Electrical terminals
  • Wiring harness condition
  • Contactor operation
  • Control board diagnostics
  • Fan motor performance
  • Coil cleanliness
  • Supply voltage

Controls, Temperature, 110 degrees F Fixed Cut-in Temperature, 120 degrees F Fixed Cut-out Temperature, Open on Rise Switch Action, Snap Disc Auto Reset Limit Switch (60T11-610000)