3L01-190 Copeland Comfort Control (White Rodgers) Limit Switch L190-40F
3L01-190 Copeland Comfort Control (White Rodgers) Limit Switch L190-40F
Replaces 4601-2358, 3-3797
The 3L01-190 Snap Disc Limit Switch (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety control designed to protect HVAC, heating, and refrigeration equipment from excessive operating temperatures. Featuring a 190°F fixed cut-out temperature and a 40°F differential, this open-on-rise switch interrupts the electrical circuit when temperatures exceed safe limits and automatically resets after cooling, helping protect critical system components from heat-related damage.
Cross-Reference
- 3L01-190
- 3L01190
- L190-40F
- 4601-2358
- 3-3797
- White-Rodgers 3L01-190
- Copeland Comfort Control 3L01-190
Direct OEM
White-Rodgers 3L01-190
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Universal HVAC Applications
- Refrigeration Equipment Manufacturers
Application
Used in HVAC and refrigeration equipment to:
- Protect equipment from overheating
- Open the safety circuit at 190°F
- Automatically reset after cooling
- Protect compressors, heaters, motors, and control circuits
- Prevent heat-related component failures
- Maintain reliable equipment operation
Related Components
- Snap Disc Limit Switch
- High Limit Control
- Fan Switch
- Fan & Limit Control
- Control Board
- Transformer
- Compressor Contactor
- Blower Relay
- Temperature Sensor
Technician Notes
The 3L01-190 is an automatic reset, open-on-rise snap disc limit switch. Under normal operating conditions the contacts remain closed. When the sensing surface reaches 190°F, the contacts open to interrupt the circuit and prevent overheating. Once temperature falls by the switch differential, the contacts automatically reset and restore circuit operation.
This limit switch replaces 4601-2358 and 3-3797 and is commonly used in HVAC, refrigeration, and equipment protection applications where automatic reset functionality is required.
Common Symptoms of Failure
- Equipment shuts down unexpectedly
- High-limit or safety circuit faults
- Intermittent operation
- No continuity through switch contacts
- Repeated temperature-related shutdowns
- System lockout conditions
- Compressor or heater protection trips
- Failure to restart reliably
Installation Tips
- Disconnect power before servicing.
- Match temperature ratings and switch action exactly.
- Verify the replacement is an "Open on Rise" switch.
- Mount securely against the original sensing surface.
- Inspect terminals for corrosion or heat discoloration.
- Check airflow and operating temperatures.
- Verify switch continuity before startup.
- Test system operation through a complete cycle.
Recommended Inspection Items
- Blower motor operation
- Airflow restrictions
- Coil cleanliness
- Electrical terminals
- Wiring harness condition
- Compressor operating temperature
- Control board diagnostics
- Supply voltage
- Ventilation around equipment