3L09-13 Copeland Comfort Control (White Rodgers) Board Mount Limit Control 240F
3L09-13 Copeland Comfort Control (White Rodgers) Board Mount Limit Control 240F
The 3L09-13 Board Mount Limit Control (White-Rodgers / Copeland Comfort Control) is an automatic reset temperature safety switch designed to protect HVAC equipment, control boards, transformers, and electrical compartments from overheating. Featuring a 240°F fixed open temperature, this compact board-mounted bimetal limit switch interrupts the circuit when excessive temperatures are detected and automatically restores operation after cooling, helping protect critical electrical components from heat-related damage and ensuring reliable equipment operation.
Cross-Reference
- 3L09-13
- 3L0913
- L240F
- White-Rodgers 3L09-13
- Copeland Comfort Control 3L09-13
- 74T Series Board Mount Limit Control
Direct OEM
White-Rodgers 3L09-13
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal HVAC Applications
Application
Used in HVAC and electrical equipment to:
- Protect control boards from overheating
- Interrupt safety circuits at elevated temperatures
- Automatically restore operation after cooling
- Protect transformers and electrical enclosures
- Prevent temperature-related component failures
- Provide automatic thermal protection
Related Components
- Board Mount Limit Switch
- Snap Disc Thermostat
- Furnace Control Board
- Transformer
- Blower Relay
- High Limit Control
- Temperature Sensor
- Safety Cutoff Switch
- Electrical Control Assembly
Technician Notes
The 3L09-13 is an automatic reset, open-on-rise board mount limit control utilizing a compact bimetal sensing disc. Under normal operating conditions, the contacts remain closed and open when the sensing surface reaches 240°F, interrupting the circuit to prevent overheating. Once temperatures fall below the factory reset point, the contacts automatically reclose and restore normal operation.
This control is commonly used in electrical compartments, transformer protection circuits, blower assemblies, control boards, electric heating equipment, and OEM HVAC applications where higher-temperature protection is required.
Common Symptoms of Failure
- Equipment shuts down unexpectedly
- Open safety circuit faults
- Intermittent operation
- Repeated over-temperature shutdowns
- Control board overheating faults
- No continuity through switch contacts
- Failure to reset properly
- Electrical compartment overheating
- Transformer thermal protection trips
Installation Tips
- Disconnect power before servicing.
- Verify the replacement temperature rating matches the original control.
- Confirm switch action is Open on Rise.
- Mount securely in the original location.
- Inspect terminals for heat discoloration or corrosion.
- Verify adequate ventilation around electrical components.
- Check switch continuity before startup.
- Test operation through a complete equipment cycle.
Recommended Inspection Items
- Control board condition
- Transformer temperature
- Wiring harness connections
- Electrical terminals
- Blower motor operation
- Airflow restrictions
- Ventilation around controls
- Relay condition
- Equipment operating temperatures
- Heat-generating components nearby
Controls, Temperature, 240 degrees F Fixed Open Temperature, 210 degrees F Fixed Close Temperature, Open on Rise Switch Action, Auto Reset, 3.12" Insertion Length, Board Mounted 1/2" Bimetal Disc Limit Switch