5D51-90 Copeland Comfort Control (White Rodgers) FAN & LIMIT CTRL, 8"
5D51-90 Copeland Comfort Control (White Rodgers) FAN & LIMIT CTRL, 8"
The 5D51-90 Fan & Limit Control (White-Rodgers / Copeland Comfort Control) is a combination furnace control designed to manage blower fan operation and provide high-temperature safety protection in residential and light commercial heating systems. Featuring an 8-inch sensing element, this control automatically starts and stops the blower based on plenum temperature while protecting the furnace from overheating through its integrated limit switch function.
Cross-Reference
- 5D51-90
- 5D5190
- White-Rodgers 5D51-90
- Copeland Comfort Control 5D51-90
Direct OEM
White-Rodgers 5D51-90
Compatible Brands
- White-Rodgers
- Emerson
- Copeland
- York
- Coleman
- Luxaire
- Goodman
- Rheem
- Universal Warm Air Furnace Applications
Application
Used in forced-air furnaces to:
- Control blower fan operation
- Provide furnace high-limit protection
- Prevent circulation of cold air at startup
- Protect heat exchangers from overheating
- Automatically cycle the blower during heating operation
- Maintain proper furnace operating temperatures
Related Components
- Fan & Limit Control
- High Limit Switch
- Fan Switch
- Furnace Control Board
- Blower Relay
- Blower Motor
- Transformer
- Thermostat
- Plenum Temperature Control
Technician Notes
The 5D51-90 is a combination fan and limit control equipped with an 8-inch sensing element for applications requiring deeper insertion into the furnace plenum. This control combines blower fan management and overtemperature protection in a single device, reducing component count and simplifying service.
Before replacement, verify insertion length, mounting dimensions, temperature settings, and electrical ratings match the original control.
Common Symptoms of Failure
- Blower fan runs continuously
- Blower fails to start
- Furnace overheats
- High-limit shutdowns
- Short cycling
- Delayed blower operation
- Inconsistent heating performance
- Excessive furnace temperatures
- No heat output
Installation Tips
- Disconnect power before servicing.
- Label all wiring before removal.
- Verify the 8-inch insertion length matches the original control.
- Fully insert the sensing element into the plenum.
- Inspect terminals for corrosion or overheating.
- Verify blower motor operation and amperage.
- Check fan and limit settings after installation.
- Run the furnace through a complete heating cycle.
Recommended Inspection Items
- Blower motor condition
- Air filter restriction
- Heat exchanger temperature rise
- Blower relay operation
- Wiring terminals
- Furnace control board
- Supply and return airflow
- Venting system
- Blower wheel cleanliness