626602 Nordyne 90–110 °F Auto-Reset Limit Switch

626602 Nordyne 90–110 °F Auto-Reset Limit Switch

  • $ 12.98
    Unit price per 
  • Save $ 6.28
Shipping calculated at checkout.


626602 Nordyne 90–110 °F Auto-Reset Limit Switch


Product Overview

The 626602 Nordyne Auto-Reset Limit Switch is a direct-fit OEM safety control for residential gas furnaces and air handlers. Factory-preset to open at 90 °F and automatically reset at 110 °F, it provides reliable protection against low-limit conditions (such as blocked airflow) without requiring manual intervention.

Key features:

  • Auto-reset design for uninterrupted operation

  • Precision bi-metal sensing element for consistent actuation

  • Compact phenolic housing with snap-in mounting


Technical Specifications

Specification Detail
Cut-out temperature 90 °F (± 5 °F)
Reset temperature 110 °F (± 5 °F)
Differential 20 °F nominal
Contact configuration SPST normally closed
Electrical rating 5 A @ 250 VAC (resistive)
Terminals ¼″ quick-connect spade
Housing material High-temperature phenolic
Mounting style Snap-in or screw retention
Dimensions (L × W × H) 1.25″ × 1.25″ × 0.75″ (approx.)
Weight 0.05 lb (23 g)


Cross-Reference Part Numbers

  • Nordyne 626602

  • Neuco 626602

  • Coleman 626602

  • OEM legacy: L90-20AUTO, L90-110F auto reset


Compatibility

Compatible with a wide range of single-stage residential furnaces and air handlers that require a 90 °F low-limit auto-reset switch, including:

  • Nordyne & Coleman N5/N6 series

  • Goodman & Amana legacy furnaces

  • York & Westinghouse standard models

  • Bryant & Payne residential units

  • American Standard Basic Heat & Pro-Line lines


Technician Notes

  • Always disconnect power and verify zero voltage before servicing.

  • Locate and remove the original low-limit switch; note its clip or bracket orientation.

  • Install the 626602 in the identical plenum or duct location to ensure accurate temperature sensing.

  • Confirm terminal seating and torque spade connections per spec to avoid arcing.

  • After installation, restore power and allow normal cycling; the switch should stay closed under proper airflow and open only if the plenum temperature falls to 90 °F.

  • Carry a spare 626602 and mounting clip for rapid field replacement.

  • Consider bundling with airflow filters and blower wheel inspections to prevent recurring low-limit trips.