colemanhvacparts.com, www.darindevries.com

632515R Nordyne Dual Pressure Switch

  • $ 50.22
    Unit price per 
  • Save $ 10.15
Shipping calculated at checkout.


632515R Nordyne Dual Pressure Switch

Product Overview

632515R is an OEM Nordyne dual pressure switch engineered to verify both inducer vacuum and positive pressure conditions in gas furnaces. It closes at –0.73" WC on the negative side and 0.43" WC on the positive side, ensuring proper airflow before ignition.  


Technical Specifications

Specification Detail
Pressure Setpoints –0.73" WC (vacuum) / 0.43" WC (positive pressure)
Switch Type Dual-pressure automatic-reset SPDT switch
Port Connection 1/4" barbed fitting for vacuum/pressure tubing
Terminals Two 1/4" male quick-connect spades
Housing Material Durable thermoplastic enclosure
Net Weight 0.03 lb
Operating Temperature –40 °F to 150 °F


Cross-Reference Part Numbers

OEM Part Number Replaces
632515R 632515


Compatibility

Fits Nordyne, Nordyne Miller, Intertherm, and private-label gas furnaces originally equipped with a dual pressure switch requiring –0.73" WC vacuum and 0.43" WC positive pressure verification. Always confirm the furnace’s data‐plate requirements before ordering.


Technician Notes

  • De-energize all power and shut off the gas supply before servicing.

  • Remove the access panel to expose the existing pressure switch.

  • Photograph or label the vacuum and pressure tubing routing as well as spade terminal connections.

  • Depress the mounting bracket tab to release the old switch; disconnect tubing and spade leads.

  • Install the new 632515R by snapping it into the bracket, pushing tubing onto the 1/4" barb, and reconnecting the spade terminals.

  • Restore power and initiate a heat call; verify the switch closes near –0.73" WC on inducer startup and opens at 0.43" WC positive pressure.

  • Use a manometer to confirm actuation accuracy and check for any tubing leaks or kinks that could cause false readings.