903428 Nordyne SP TO HSI CONVERSION KIT
903428 Nordyne SP TO HSI CONVERSION KIT
The 903428 conversion kit upgrades Nordyne furnaces from a standing‐pilot (SP) ignition system to a reliable hot‐surface ignition (HSI) platform. By replacing the constant pilot flame with an electronic ceramic ignitor, this kit reduces fuel waste, minimizes pilot outage service calls, and improves overall system reliability.
Key Features
-
Complete SP-to-HSI conversion package for Nordyne gas furnaces
-
Includes control module, ceramic hot‐surface ignitor, harnesses, and mounting hardware
-
Pre-wired, plug-and-play connectors for fast field installation
-
Integrated flame sensor for accurate flame detection
-
Durable stainless‐steel ignitor rated for extended service life
Compatibility
-
OEM part number 903428 (Nordyne)
-
Neuco cross-reference part number 212647
-
Designed for Nordyne single-stage gas furnaces originally equipped with standing-pilot ignition
-
Ideal for residential applications up to typical furnace BTU ratings
Technical Specifications
| Specification | Details |
|---|---|
| Part Number | 903428 |
| Conversion Type | Standing Pilot to Hot Surface Ignition (SP→HSI) |
| Kit Contents | Control module; HSI assembly; wiring harness; mounting hardware |
| Voltage | 120 VAC control board |
| Ignitor Material | Stainless steel ceramic |
| Weight | 16.5 lb |
| Dimensions (L×W×H) | 30 × 19 × 15 in |
| Country of Origin | Mexico |
Installation & Maintenance
-
Shut off gas supply and electrical power to the furnace.
-
Remove the existing SP assembly and disconnect pilot tubing.
-
Mount the hot‐surface ignitor in place of the pilot orifice and secure per instructions.
-
Install the control module in the furnace cabinet and connect all harness plugs.
-
Restore gas and power, then initiate a call for heat to verify proper ignition sequence.
-
Observe ignitor glow and flame sensor feedback; adjust flame sensor gap if needed.
-
Perform routine inspections of ignitor condition and control board connections.
Why Upgrade?
-
Eliminates constant pilot flame, cutting fuel consumption and costs
-
Reduces service calls related to pilot outages and draft issues
-
Modernizes older Nordyne units with OEM-quality electronics
-
Enhances safety with accurate flame sensing and fault diagnostics
-
Extends furnace life by leveraging durable HSI technology