921951 Nordyne Evap Coil Tube And Fin 2 Ton
921951 Nordyne Evap Coil Tube And Fin R22 / R410A 2 Ton
Normal Stock Item
Model: 921951 Type: Tube‑and‑Fin Evaporator Coil Tonnage: 2 Ton (24,000 BTU) Refrigerant: R22 / R410A Configuration: Uncased coil assembly Typical Applications:
-
Intertherm / Miller mobile home systems
-
Nordyne split systems
-
R22 → R410A upgrade replacements
📐 Functional Notes
-
Tube‑and‑fin coils are older‑style Nordyne designs used heavily in manufactured housing.
-
Compatible with both refrigerants because the coil construction itself is refrigerant‑agnostic; the metering device (piston/TXV) determines refrigerant behavior.
-
Often paired with 2‑ton outdoor units and electric furnaces in mobile homes.
Nordyne’s tube‑and‑fin replacement coils follow a predictable pattern:
-
921951 → 2 ton
-
921952 → 2.5 ton
-
921953 → 3 ton
-
921954 → 5 ton ← your part
The jump from 3‑ton to 5‑ton is normal in Nordyne’s older mobile‑home coil catalog — they did not produce a 4‑ton tube‑and‑fin in this series. So with that being said if you have a 4 ton unit use a 5 ton coil it will produce 4 tons of A/C
Product Description
The 921951 is a genuine Nordyne evaporator coil featuring a tube-and-fin design optimized for both R22 and R410A refrigerants. Its densely packed aluminum fins and copper tubing deliver exceptional heat transfer, maintaining airflow and system efficiency in residential split-system and light-commercial applications. Built to OEM tolerances, this coil resists corrosion and wear for years of dependable service.
Options
669855R HORIZONTAL DRAIN PAN
669564R 2 Ton R410a TXV Valve
920668A 2 Ton R410A RT6 Expansion Valve
Key Features
-
Universal compatibility with R22 and R410A systems
-
Tubing: 3/8 " copper, 4-row design for high capacity
-
Fins: hydrophilic-coated aluminum to repel moisture
-
Heavy-gauge condensate drain pan integrated into cabinet
-
Factory leak-tested and pressure-rated for up to 580 psig
-
Fits standard cabinet openings for easy retrofit
Technical Specifications
| Specification | Detail |
|---|---|
| Part Number | 921951 |
| Refrigerants | R22 / R410A |
| Coil Rows | 4-row copper tubing |
| Tube Diameter | 3/8 inch (9.5 mm) |
| Fin Material & Coating | Aluminum, hydrophilic coating |
| Face Area | 24 in × 22 in (610 mm × 558 mm) |
| Cabinet Depth | 7 in (178 mm) |
| Maximum Working Pressure | 580 psig (40 bar) |
| Operating Temperature Range | –40 °F to 160 °F (–40 °C to 70 °C) |
| Drain Connection | Integrated 3/4 in male NPT |
| Weight | 28 lb (12.7 kg) |
Compatibility
This OEM coil directly replaces Nordyne 921951 and fits a wide array of split-system air handlers and packaged units from Nordyne, Coleman, Comfortmaker, Amana, Ducane, and private labels:
-
Nordyne / Coleman / Comfortmaker
-
Air handlers: 38AJ, 42AJ, 46AJ series
-
Package units: CPN, CKL, CNB (2–5 ton R22/R410A)
-
-
Amana / Ducane
-
Model lines: ACCP, ACC (R410A variants), RG4, SH4 rooftops
-
-
Cross-Reference Equivalents
-
REPLCOIL01HS
-
GSIStore O2HS-24-22-7
-
HD Supply EVCO-4R-24-22
-
Ordering & Support
-
SKU: 921951
-
Stock Status: Available for immediate shipping