colemanhvacparts.com, www.darindevries.com

HH12ZB180 Carrier L180-40F 3" Limit Switch

  • $ 43.53
    Unit price per 
  • Save $ 4.35
Shipping calculated at checkout.


HH12ZB180 Carrier L180-40F 3" Limit Switch

The Carrier HH12ZB180 is a genuine OEM L180-40F high-limit switch used in Carrier, Bryant, and Payne gas furnaces. This 3-inch insertion-depth limit switch opens at 180°F and automatically resets after the temperature drops by 40°F, protecting the heat exchanger from overheating caused by restricted airflow, dirty filters, blower failure, or over-firing.

This switch is the factory-authorized replacement for older Carrier rollout and high-limit switches and installs directly into standard Carrier primary limit brackets with no modifications. It maintains original furnace safety certifications and proper cycling behavior.

Grounded product data:

  • 3" insert, L180-40 calibration, automatic reset, and OEM compatibility with Carrier/Bryant/Payne .

  • It replaces HH12ZA178, HH12ZA178A, P331-2204, and P331-2223 .

  • SPST, 3" size, L180-40 rating, and OEM Carrier listing .

  • 180°F high-limit thermostat, OEM for Carrier/Payne, and lists the same replacement part numbers .


Cross-Reference

Direct OEM

  • HH12ZB180 — Carrier/Bryant/Payne L180-40F Limit Switch

Replaces / Interchange

  • HH12ZA178

  • HH12ZA178A

  • P331-2204

  • P331-2223

Compatible Furnace Families

  • Carrier 330AAV, 331AAV, 340AAV series

  • Carrier 58DFA070 series (multiple sub-models)

  • Payne & Bryant equivalents (same OEM platform)


Technician Notes

  • Trip Temperature: 180°F

  • Differential: 40°F (automatic reset)

  • Length: 3" insertion depth

  • Circuit: SPST, normally closed (opens on temperature rise)

  • Function: Protects heat exchanger from overheating

  • Common Symptoms:

    • Furnace starts then stops (high-limit opening)

    • Blower runs continuously while burners stay off (open limit)

    • Short-cycling or failure to ignite

  • Do NOT up-rate the limit switch — using a higher temperature limit is unsafe and can damage the heat exchanger or cause fire hazard

  • Check airflow issues first: dirty filter, blocked return, blower failure, or vent restriction.

Limit control switch. L180F-40. Back plate measures 1-7/8" x 2-3/4" with two 1/4" spade terminals. 3" arm length. Limit closes at 180F and opens back up at 140F. 0212R and

Replaces 1NT23L-3644

New part Carrier HH12ZB180.

HH12ZB180