ICM2805A Control Board Furnace Nordyne OEM Replacement
ICM2805AÂ Control Board Furnace Nordyne OEM ReplacementÂ
Â
Nordyne OEM Replacement Control
Low-Cost Form, Fit And Functional Replacement Board
The ICM2805A is a low cost replacement for Nordyne 624631 furnace control board which is used to control gas valve, inducer draft motor, circulating blower and hot surface ignitor.
- Low cost form, fit and functional OEM replacement control board for Nordyne: 624631
- For use with G3, G4, G5, G6, M2 and M3 furnace modules
- Controls gas valve, inducer draft motor, circulating blower and hot surface ignitor
- Monitors timing, trial for ignition, flame sensing, lockout, plus pressure, rollout and limit switches
- Microprocessor-based precision
- Twinning compatible with another ICM2805A furnace control
- Diagnostic LEDs aid in testing and troubleshooting
REPLACES:
Nordyne:Â 624631, 624631B (for use with G3, G4, G5, G6, M2 and M3 furnace modules)
Generic control board replaces Nordyne 624631 and 903106-kit. Â Board is typically found on G3R, G4R, G5R Nordyne furnaces, among other models as listed below. Â
Nordyne circuit board for M2 and M3 series of furnaces. Also used in G3, G4, G5 & G6 units. For a spare or replacement fuse, order 3A fuse G32-189. Â To purchase the original version of this board, see part # 903106.Â
Replaces 624538, 6245380, 624557, 6245570, 624564, 6245640, 624-5640, 624591, 6245910, 624628, 6246280, 624631, 624631A, 624631-A, 624631B, 624631-B, 6246310, 902378, 902696, 902896, 903106.
Replaces:
Nordyne:Â 624631, 624631B (for use with G3, G4, G5, G6, M2 and M3 furnace modules)
CONTROL LIGHT STATUS
RED
Steady ON Control OK
Steady OFF No power
Rapid Flash - False flame or gas valve relay shorted
1 Flash - Limit circuit open or external load on "W" (does not apply to deck switch, see below) .
2 Flashes - Pressure switch is stuck open with inducer blower running.
3 Flashes - Pressure switch is closed with inducer off
4 Flashes - Ignition failure (check ground)
5 Flashes 115 vac & neutral reversed or no ground
YELLOW
Steady ON - Good flame signal
Blinking - Weak flame signal
Steady OFF - No flame signal
Control board operation:
- Controls gas valve, inducer draft motor, circulating blower and hot surface ignitor
- Monitors timing, trial for ignition, flame sensing, lockout, plus pressure, rollout and limit switches.
- Microprocessor-based precision
- Twinning compatible with another ICM2805 furnace control
- Diagnostic LEDs aid in testing and troubleshooting
- Ignitor: 5A, 120 VAC
- Cool Blower: 10A, 2HP, 240 VAC
- Heat: 5A, ½ HP, 250 VAC
- Inducer Blower: 4A, 120 VAC
- Gas Valve: 1A, 24 VAC
- Humidifier Motor: 0.5A, 24 VAC
- Electronic Air Cleaner: 1A, 120 VA