S1-031-01932-002 Coleman Integrated Control Board OEM, DGAT, DGAA, DGAH
S1-031-01932-002 Coleman Integrated Control Board OEM, DGAT, DGAA, DGAH
Product Description
The S1-031-01932-002 Integrated Control Board is a genuine OEM replacement control board designed for select Coleman®, York®, Luxaire®, and Guardian® gas furnaces. This integrated furnace control (IFC) board serves as the central operating system for the furnace, managing ignition sequencing, blower motor operation, flame sensing, safety circuits, and system diagnostics. Replacing a faulty control board can restore dependable heating performance and proper furnace operation.
Manufactured to OEM specifications for reliable compatibility, performance, and long service life.
Features
- Genuine OEM Coleman replacement part
- Integrated Furnace Control (IFC) Board
- Controls ignition and burner operation
- Manages blower motor timing
- Monitors furnace safety circuits
- Diagnostic and troubleshooting capabilities
- Direct OEM replacement
- Reliable electronic control performance
Technical Notes
- Part Number: S1-031-01932-002
- Product Type: Integrated Control Board
- Application: Gas Furnaces
- OEM Replacement Component
- Controls ignition sequence, blower functions, flame sensing, and safety monitoring
- Supports furnace diagnostics and fault detection
- Verify board number and furnace model compatibility before ordering
- Professional installation recommended
Fits Models
Compatible with select Coleman furnace series including:
- Coleman DGAA Series
- Coleman DGAH Series
- Coleman DGAT Series
May also fit select York, Luxaire, and Guardian equivalents using the same control platform. Always verify the original board number before ordering.
Cross Reference
- S1-031-01932-002
- 031-01932-002
- Coleman Integrated Control Board
- Coleman IFC Board
- DGAA Control Board
- DGAH Control Board
- DGAT Control Board
- Furnace Control Board
- OEM Integrated Furnace Control
Use with furnace models DGAT, DGAA, DGAH, An others.
Sometimes referred to as a circuit board or ignition control. For a spare or replacement fuse, order a 3A fuse G32-189 found below.
Replaces 7990-319P, ICM2801, 7990-320, 7990-320P, 031-01910-000, 031-01932-000, 031-01932-001, 03101932002 & 031-01932-002, S1-03101910000
Diagnostic Flash Codes
Steady light on - normal operation.
One flash - ignition failure.
Two flashes - combustion air switch stuck closed.
Three flashes - combustion air switch failed to close.
Four flashes - limit switch open.
Five flashes - gas valve energized with no call for heat.
Rapid flashing - reversed polarity.
Note: Color of light is green.
The 2-minute video below illustrates how this board controls the operation of your furnace:
VIDEO <----
-
Safety First:
- Ensure that power to the HVAC system is turned off at the circuit breaker before attempting any installation.
-
Locate the Control Board:
- Identify the existing control board in your HVAC system. The integrated control board is often found within the furnace or air handler.
-
Document Wiring Connections:
- Before disconnecting any wires, take clear photos or make a diagram of the existing wiring connections on the old control board. This will help you reconnect the wires correctly to the new board.
-
Power Off and Disconnect:
- Turn off the power to the HVAC system at the circuit breaker.
- Disconnect any wiring harnesses or connectors attached to the old control board.
-
Remove Old Control Board:
- Carefully remove the old control board from its mounting bracket. This might involve removing screws or other fasteners.
-
Install New Control Board:
- Mount the new control board onto the bracket in the same position as the old one.
-
Connect Wiring:
- Connect the wires to the corresponding terminals on the new control board based on your documentation.
-
Double-Check Connections:
- Double-check all wiring connections to ensure they match your documentation and are secure.
-
Power On:
- Turn the power back on at the circuit breaker.
-
Test System:
- Test your HVAC system to ensure that it operates correctly. Check for proper heating or cooling, and make sure all components are functioning as expected.
If you have the specific installation instructions provided by Coleman for the S1-031-01932-002 control board, please follow those instructions precisely. If not, consider reaching out to Coleman's customer support or consulting with a professional HVAC technician to ensure a safe and accurate installation.