S1-031-03010-000 Coleman Integrated Control Board

  • $ 244.44
    Unit price per 
  • Save $ 24.44
Shipping calculated at checkout.


S1-031-03010-000 Coleman Integrated Control Board 

1 Year Warranty

The S1-031-03010-000 Integrated Control Board is a genuine OEM replacement control board designed for select Coleman® and York® gas furnaces. This control board serves as the central operating system of the furnace, managing ignition sequence, blower operation, safety monitoring, and heating cycles. Replacing a failed control board can restore proper furnace functionality and reliable system performance.

Engineered to OEM specifications for dependable operation and compatibility with approved furnace models.

Features

  • Genuine OEM replacement control board
  • Designed for Coleman and York furnace applications
  • Controls ignition, blower, and safety functions
  • Reliable microprocessor-based operation
  • Direct-fit replacement for compatible units
  • Supports efficient furnace performance
  • Durable construction for long service life
  • Factory-specified HVAC replacement component

Technical Notes

  • Part Number: S1-031-03010-000
  • Product Type: Integrated Furnace Control Board
  • Application: Residential and light commercial gas furnaces
  • Brands: Coleman®, York®
  • Function: Controls ignition sequence, blower timing, safety circuits, and diagnostics
  • OEM Replacement Part
  • Verify furnace model and board number before ordering
  • Professional installation recommended

Cross Reference

  • S1-031-03010-000
  • 031-03010-000
  • Coleman Integrated Control Board
  • York Furnace Control Board
  • Furnace IFC Board
  • Integrated Furnace Control Module
  • OEM Furnace Control Board Replacement

S1-03103010000 replaces S1-031-01972-100, S1-031-00662-000, S1-03109166000

Single stage Coleman circuit board. Includes control board 331-02956-000 does not include wiring harness adapters.

I

Replaces part number 2702-382, 2702-382P, 2702-380, 2702-380P, 2702-310, 2702-310/A, 2702-310P/A, 2702-382, 2702-382P/A, 031-09167-000, 025-37014-000, 025-37015-000, 031-01933-000, 031-01267-000, 031-01267-001, 031-00662-000, 031-01250-000, 031-01266-000, 031-01284-000, 031-01973-000, 031-01972-000, 035-17344-000, 035-17344-001, 473-23151-000 & 473-01972-100. 265901 & 265902.

Also replaces S1-03109167000, S1-03101933000, S1-03101267000, S1-03101267001, S1-03100662000, S1-03101250000, S1-03101266000, S1-03101284000, S1-03101973000 & S1-03101972000, P031–01267–001

Diagnostic fault codes are as follows:

Slow green - normal operation- NORMAL
Slow amber - normal operation with call for heat - NORMAL
Steady on red - control failure - Replace control board
Rapid red - twinning error, incorrect 24V phasing- Transformer low voltage wires
Rapid amber - low flame sense current - Clean Flame Sensor with steel wool
1 red flash - flame present with gas off - Bad Gas valve leaking change gas valve
2 red flashes - pressure switch stuck closed - Bad pressure switch replace
3 red flashes - pressure switch stuck open- Bad pressure switch replace
4 red flashes - limit switch open / open fuse - Check manual limits push to reset
5 red flashes - rollout switch open / open fuse -Check manual limits push to reset
6 red flashes - pressure switch cycle lockout - Bad pressure switch or inducer air flo
7 red flashes - ignition lockout due to retries - Hot sureface igniter or flame sensor
8 red flashes - ignition lockout due to recycles-Hot sureface igniter or flame sensor
9 red flashes - grounding or line polarity fault- Ground wire on furnace or elec box
10 red flashes - gas flow with no call for heat - Faulty gas valve
11 read flashes - limit switch open - Blower failure - Reset manual limit on blower
4 amber flashes - Y present with no G call- Check Thermostat wires

To retrieve fault codes, push and release the LAST ERROR button. The LED will flash up to five stored fault codes beginning with the most recent. If there are no fault codes in memory, the LED will flash two green flashes.

To clear the fault code memory, push and hold the LAST ERROR button for at least five seconds. The LED will flash three green flashes when the memory has been cleared.

  1. Green Flashes:

    • One green flash: Normal operation with no call for heat (thermostat not requesting heat).
    • Two green flashes: No error codes stored in memory.
    • Three green flashes: Memory cleared after pressing the LAST ERROR button.
    • Rapid green flash: Used during factory testing.
  2. Amber Flashes:

    • One amber flash: Normal operation with a call for cooling (thermostat requesting cooling).
    • Two amber flashes: Normal operation with a call for heat (thermostat requesting heat).
    • Three amber flashes: Normal operation; wall thermostat temperature fulfilled, furnace burner ending cycle.
    • Four amber flashes: Possible restriction in the circulating air system affecting heating capability.
    • Five amber flashes: Restriction in the vent or combustion air system reducing heating capability.
    • Rapid amber flash: Possible low flame due to a dirty or mispositioned low flame sensor rod.
  3. Red Flashes:




We Also Recommend