0130F00010S Amana-Goodman FLAME SENSOR
0130F00010S Amana-Goodman FLAME SENSOR
The 0130F00010S Flame Sensor is a
o
genuine OEM replacement flame-sensing component designed for use in select Goodman, Amana, and Daikin gas furnaces. This critical safety device verifies burner flame presence during furnace operation and sends a flame rectification signal to the ignition control board. If the flame is not properly detected, the control system will shut off the gas valve to prevent unsafe operation.
Manufactured to original equipment specifications, the 0130F00010S Flame Sensor helps ensure reliable ignition verification, safe furnace operation, and dependable heating performance. It is commonly replaced when furnaces experience intermittent ignition, flame-proving errors, or nuisance lockouts.
Cross-Reference
- 0130F00010S
- Goodman 0130F00010S
- Amana 0130F00010S
- Flame Sensor
- Furnace Flame Sensor
- Flame Rod Assembly
- Flame-Proving Sensor
Direct OEM
Yes – Genuine Goodman / Amana OEM replacement flame sensor.
Compatible Brands
- Goodman
- Amana
- Daikin
Always verify compatibility using the furnace model and serial number before ordering.
Application
- Gas furnaces
- Residential heating systems
- Flame rectification circuits
- Ignition verification systems
- Furnace safety controls
- OEM replacement repairs
Related Components
- 0230K00001 Mini Hot Surface Ignitor
- Hot Surface Ignitors
- Ignition Control Boards
- Gas Valves
- Pressure Switches
- Draft Inducer Motors
- Limit Switches
- Burner Assemblies
Technician Notes
- Genuine OEM Goodman flame-sensing component.
- Confirms burner flame presence to the furnace control board.
- Essential safety device within the ignition system.
- Flame sensors can often be cleaned if coated with oxidation, but replacement is recommended when the sensor is damaged or unreliable.
- Inspect burner grounding and ignition performance when troubleshooting flame-sensing issues.
- Replace if the rod is deteriorated, cracked, or produces intermittent flame-proving signals.
Common Symptoms of Failure
- Furnace ignites then shuts off
- Flame sensor fault codes
- Ignition lockout conditions
- Repeated ignition attempts
- Intermittent heating operation
- Burner cycles off unexpectedly
- No heat condition
- Flame-proving failures
Installation Tips
- Disconnect electrical power before servicing.
- Locate the flame sensor near the burner assembly.
- Remove the retaining screw and disconnect the sensor.
- Inspect burner and grounding surfaces.
- Install the replacement sensor in the original position.
- Reconnect wiring securely.
- Restore power and initiate a heating cycle.
- Verify stable burner operation and proper flame sensing.
Recommended Inspection Items
- Hot surface ignitor condition
- Burner assembly cleanliness
- Ignition control board
- Gas valve operation
- Pressure switch function
- Draft inducer performance
- Grounding integrity
- Heat exchanger condition
- Air filter cleanliness