7660-Cap for Sight Glass
7660-Cap for Sight Glass (Just the Cap)
The 7660-Cap Observation Burner Cap is a replacement burner observation port cap designed for use with the 7660-3661 Coleman Observation Burner Cap Assembly. This part includes the metal cap only and does not include the fire-rated sight glass or gasket. It is intended for replacing a damaged, corroded, or missing observation cap while reusing an existing sight glass and gasket when they remain in serviceable condition.
The observation cap helps secure the burner viewing window assembly and maintain proper sealing of the burner compartment, allowing safe visual inspection of burner flame operation without disrupting furnace performance.
Parts Breakdown for 7660-3661 Assembly
| Component | Part Number |
|---|---|
| Observation Cap Only | 7660-Cap |
| Fire-Rated Sight Glass | SG-511 |
| High-Heat Sight Glass Gasket | G-181 |
| Complete Assembly | 7660-3661 |
Cross-Reference
- 7660-Cap
- 7660 Cap
- Coleman Observation Cap
- Burner Observation Cap
- Sight Glass Cap
- Observation Window Retainer Cap
Direct OEM
Designed for use with Coleman burner observation assemblies.
Compatible Brands
- Coleman
- York
- Luxaire
- Fraser-Johnston
- Evcon
Verify compatibility with the original burner observation assembly before ordering.
Application
- Gas furnaces
- Burner observation ports
- Sight glass assemblies
- Burner inspection windows
- Furnace combustion compartments
- OEM maintenance and repair
Related Components
- 7660-3661 Observation Burner Cap Assembly
- SG-511 Fire-Rated Sight Glass
- G-181 High-Heat Gasket
- 7706A3171 Burner Observation Door Gasket
- Flame Sensors
- Ignitors
- Burner Assemblies
- Draft Inducers
Technician Notes
- Replacement cap only.
- Does not include sight glass.
- Does not include gasket.
- Used as part of the 7660-3661 burner observation assembly.
- Inspect sight glass and gasket whenever servicing the cap.
- Replace cracked glass or damaged gaskets during reassembly.
- Verify cap seats evenly to maintain proper burner compartment sealing.
Common Reasons for Replacement
- Corroded cap
- Damaged retaining cap
- Stripped threads or mounting points
- Missing observation cap
- Inspection window service
- Burner compartment maintenance
Installation Tips
- Turn off furnace power and gas supply.
- Allow furnace components to cool completely.
- Remove the damaged observation cap.
- Inspect the SG-511 sight glass for cracks or discoloration.
- Inspect the G-181 gasket for wear or compression damage.
- Install the replacement 7660-Cap.
- Ensure proper seating and sealing.
- Verify burner compartment integrity after installation.
Recommended Inspection Items
- SG-511 sight glass condition
- G-181 gasket condition
- Burner assembly
- Flame sensor
- Ignitor
- Observation door gasket
- Heat exchanger area
- Combustion chamber seals